Unit Specifications - Climataster

    ? Job: Hi Delta - Type P Engineer: Commercial Pool Heaters

    Contractor: Models 1802B-2342B Prepared By: Date:

    Model: Indoor/Outdoor: MBTUH Input:

     Sealed Combustion Chamber

    100% Factory Fire Tested

    Efficiency: 85%

    Minimum Non-condensing Inlet Temperature: 105?F Thermal Shock Proof Heat Exchanger

    Limited Twenty-year Thermal Shock Warranty

    Limited Five-year Heat Exchanger Warranty

    Full Safety Diagnostics with Fault History

    PolyTuf Powder Coated Cabinet

    No Combustible Floor Shield Required Patent No. 7,044,124 Fan-assisted

    Standard “H” Bypass Shown Non-ferrous Bypass Patented Burner Security Blanket

Heat Exchanger Gas Train Options

    ; Brass Headers ; Combination Valves C-6 Ignition Module, Manual Reset ; ASME Inspected and Stamped ; On/Off Firing D-21 TruSeal? Direct Vent 160 PSIG Working Pressure ; Low Gas Pressure Switch, Manual Right Side ; National Board Approved ; Fuel Left Side (Model 1802B ; Cupro Nickel Finned Tubing Natural Gas Only)

    ; ASME Steel Tube Sheet Propane Gas F-10 Low Water Cut-off, Remote ; Silicone High Temp O-Rings ; Design Certified ANSI Z21.56/ Probe

    ; 125 PSIG ASME Pressure Relief Valve CSA 4.7 (P models) P-__ Cold Water Run System ; Temperature and Pressure Gauge ; Design Certified ANSI Z21.10.3/ (See Page 3) ; Water Connections CSA 4.3 (WHP models) S-2 Dual High Gas Pressure Left Standard Switches, Manual Reset Burner Right Option A-6 X-1 SureRack Kit ; Ultra-low NOx: ; Bronze Pump, 120V, 60Hz X-2 SureRack Kit Above Grade Less than 20 PPM ; Non-ferrous Pool Bypass Add-on (used with X-1) Y-241 Temperature Controller, Construction Controls 1-4 Stages ; Indoor/Outdoor Construction ; 120V, 60Hz, 1; Power Supply ; Enclosed Front Controls Regulatory Agency Requirements ; 120/24V 60Hz Transformer G-1 CSD-1 ; 100% Shut-off/Lockout Venting ; Hot Surface Ignition Systems (2) ; Vent Location ; Remote Flame Sensors (2) Top Standard ; High Limit Control, Auto Reset Rear Option D-14 ; On/Off Power Switch ; Vent Termination Cap ; Manual Shut-off, Front-mounted Outdoor Option D-11 ; Flow Switch Indoor, Horizontal ; Blocked Vent Pressure Switch Option D-15 ; Combustion Air Proving Switches Indoor, Vertical (by others) ; Economaster Pump Time Delay ; Combustion Air ; Poolstat In-Line Filter Kit (TruSeal ; Diagnostic Panel with LCD Display only) Option D-17 2 Lines, 20 Characters Air Intake Elbow

    Option D-16

    Catalog No.: 6000.342D Effective: 9-01-09 Replaces: 6-22-08

Hi Delta Type P

    Models 1802B-2342B Model

    Standard “H” Bypass

    Max. Flow Model GPM ?P (ft) ?T

    P 1802B 132 18.3 23

    WHP 2002B 132 19.0 26

    WHP 2072B 132 19.0 27 WHP 2342B 132 21.4 30

     Model MBTUH Amp Draw A Pump Shipping K T W Width HP Weight (Lbs.) Input Output Heater Pump

    P 1802B 1800 1530 91-1/8 14 10 28-1/8 <12 11 3/4 1350

    WHP 2002B 1999 1699 102-1/2 14 10 31-15/16 <12 14** 1 1450

    WHP 2072B 2070 1760 102-1/2 14 10 31-15/16 <12 14** 1 1450

    WHP 2342B 2340 1989 113-7/8 16 10 35-11/16 <12 21** 1-1/2 1520

     Dimensions are in inches. Ratings shown are for elevations up to 4,500 feet and for natural or propane gas. For installation at elevations over 4,500 feet, please contact manufacturer.

     ** Requires separate circuit breaker

Hi Delta Type P

    Models 1532B-2342B (Cold Water Run Option) Model

    Cold Water Run Option

    Max. Flow Model GPM ?P (ft) ?T

     P 1532B 132 16.5 20

     P 1802B 132 18.3 23

     WHP 2002B 132 19.0 26

    WHP 2072B 132 19.0 27

     WHP 2342B 132 21.4 30

     Injector Shipping MBTUH Amp Draw A Pump Model K T W Pump Weight Width Hp Input Output Heater Pump Hp (Lbs.)

    P 1532B 1530 1301 79-7/8 12 10 24-3/8 <12 12 3/4 1/3 1225

    P 1802B 1800 1530 91-1/8 14 10 28-1/8 <12 12 3/4 1/3 * 1460

    WHP 2002B 1999 1699 102-1/2 14 10 31-15/16 <12 14 1** 3/4 * 1560

    WHP 2072B 2070 1760 102-1/2 14 10 31-15/16 <12 14 1** 3/4 * 1560

    WHP 2342B 2340 1989 113-7/8 16 10 35-11/16 <12 21 1-1/2** 3/4 * 1620

     Dimensions are in inches. Ratings shown are for elevations up to 4,500 feet and for natural or propane gas. For installation at elevations over 4,500 feet, please contact manufacturer.

    *Separate 120 VAC or 240 VAC 1Ø power required for Cold Water Run option ** Requires separate circuit breaker