DOC

Mass Meter Product Category & Test Requirements

By Jerome Hall,2014-12-03 02:50
8 views 0
Mass Meter Product Category & Test Requirements

    NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions

    Appendix C

    Proposed Revisions to NCWM Publication 14, Policy C, Product Families for Meters

    By Henry Oppermann and Mike Keilty Following October 2009 Sector Meeting

C. Product Families for Meters

    When submitting a meter for evaluation, the manufacturer must specify the product family and critical parameters for which the meter is being submitted.

    The product family and the specific product subgroup covered by the Certificate are to be identified on Page 1 of the Certificate of Conformance. More detailed information, including the typical product types found in the subgroup, is to be included in the application section of the Certificate.

    Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

    Test B: To cover a range of the following Test F To cover a range of the following Test C - To cover a range of products Test E To cover a range of products products, test with one product having a low products, test with one product having a within each product category, test within each product category, test specific gravity and test with a second product specified conductivity. The Certificate of with one product having a low viscosity with one product having a low having a high specific gravity. The Certificate Conformance will cover all products in both and test with a second product having a kinematic viscosity and test with a of Conformance will cover all products in all of the families with conductivity equal to or high viscosity within each category. second product having a high product categories listed in the table within above the conductivity of the tested liquid. The Certificate of Conformance will kinematic viscosity within each the specific gravity range tested. cover all products in the product category. The Certificate of

    category within the viscosity range Conformance will cover all products

    tested. in the product category within the

    kinematic viscosity range tested.

    Product Category: Fuels, Lubricants, Product Category: Fuels, Lubricants, Typical Specific Product Typical Product

    Industrial and Food Grade Liquid Oils Industrial and Food Grade Liquid Oils Products Gravity* Category Products Category

    (FL&O) (FL&O) (60 ?F)

    Asphalt FL&O Gasoline FL&O Typical Reference Typical Reference

    Products Viscosity* (60 F) Products Viscosity*

    (60 ?F) Asphalt Heated JP4 FL&O Centipoise (cP) Centipoise (cP) Avgas FL&O Jet A-1 FL&O Gasoline 0.28 Gasoline 0.28 Jet A FL&O JP7 & JP8 FL&O JP4 1.02 JP4 1.02 Jet B FL&O Kerosene FL&O Jet A-1 1.36 Jet A-1 1.36 Spindle Oil FL&O JP5 FL&O JP7 & JP8 1.82 JP7 & JP8 1.82 Adjuvants 0.7 to 1.2 CC Corn Oil FL&O Kerosene 1.94 Kerosene 1.94

    NTEP - B33

NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

     Cooking Oils FL&O JP5 1.94 JP5 1.94 Banvel 0.7 to 1.2 CC

    Fumigants 0.7 to 1.2 CC Diesel Fuel FL&O Corn Oil 4 Corn Oil 4 Fungicides 0.7 to 1.2 CC Biodiesel above B20 FL&O Cooking Oils 9.93 Cooking Oils 9.93 Herbicides 0.7 to 1.2 CC Light Oil FL&O Diesel Fuel 10 Diesel Fuel 10 Insecticides 0.7 to 1.2 CC Sunflower Oil FL&O Biodiesel above 10.12 Biodiesel above 10.12

    B20 B20 Paraquat 0.7 to 1.2 CC Soy Oil FL&O Light Oil 13.47 Light Oil 13.47 Prowl 0.7 to 1.2 CC Olive Oil FL&O Sunflower Oil 90.1 Sunflower Oil 90.1 Round-up 0.7 to 1.2 CC Vegetable Oil FL&O Soy Oil 90.6 Soy Oil 90.6 Touchdown 0.7 to 1.2 CC Bunker Oil FL&O Olive Oil 116.8 Olive Oil 116.8 Treflan 0.7 to 1.2 CC Avgas FL&O Vegetable Oil 133 Vegetable Oil 133 Ammonia 1.16 to 1.37 Fert Jet A FL&O Bunker Oil 11,200 Bunker Oil 11,200 Nitrate

    Crude Oil 0.79 to 0.97 FL&O Jet B FL&O Avgas 1.5 to 6 Avgas 1.5 to 6 Lubricating 0.80 to 0.90 FL&O Asphalt FL&O Jet A 1.5 to 6 Jet A 1.5 to 6 Oils

    Peanut Oil 0.9 to 1.0 FL&O Peanut Oil FL&O Jet B 1.5 to 6 Jet B 1.5 to 6 Hexane 0.66 Sol Gen SAE Grades FL&O Asphalt 100 to 5000 Asphalt 100 to 5000 Diesel Fuel 0.72 FL&O Lubricating Oils FL&O Peanut Oil 11 to 110 Peanut Oil 11 to 110 Gasoline 0.72 FL&O Crude Oil FL&O SAE Grades 192 to 3626 SAE Grades 192 to 3626 Kerosene 0.75 FL&O 6 Oil (#5, #6) FL&O Lubricating Oils 20 to 1000 Lubricating Oils 20 to 1000 Jet A-1 0.76 FL&O Fuel Oil (#1, #2, #3, FL&O Crude Oil 3 to 1783 Crude Oil 3 to 1783

    #4)

    JP4 0.76 FL&O Spindle Oil FL&O 6 Oil (#5, #6) 66 to 13,000 6 Oil (#5, #6) 66 to 13,000 JP5 0.76 FL&O Acetone Sol Gen Fuel Oil (#1, #2, 8 to 88 Fuel Oil (#1, #2, 8 to 88

    #3, #4) #3, #4) JP7 0.76 FL&O Hexane Sol Gen Spindle Oil Spindle Oil JP8

    Ethanol 0.79 Alc Gly Acetates Sol Gen Product Category: Solvents General Product Category: Solvents General

    (Sol Gen) (Sol Gen) Isopropyl 0.79 Alc Gly MEK Sol Gen Typical Reference Typical Reference

    Products Viscosity* (60 ?F) Products Viscosity*

    (60 ?F) Acetone 0.8 Sol Gen Toluene Sol Gen Centipoise (cP) Centipoise (cP) Methanol 0.80 Alc Gly Xylene Sol Gen Acetone 0.34 Acetone 0.34

    NTEP - B34

    NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions

    Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

     Ethylacetate Sol Gen Hexane 0.34 Hexane 0.34 Butanol 0.81 Alc Gly

    Isobutyl 0.81 Alc Gly Methylene-Chloride Sol Chl Acetates 0.44 Acetates 0.44 MEK 0.81 Sol Gen Trichloro-Ethylene Sol Chl MEK 0.45 MEK 0.45 Biodiesel above 0.86 FL&O Carbon Tetra-Sol Chl Toluene 0.62 Toluene 0.62 B20 Chloride

    Light Oil 0.86 FL&O Perchloro-Ethylene Sol Chl Xylene 0.86 Xylene 0.86 Toluene 0.87 Sol Gen Methanol Alc Gly Ethylacetate 1.36 Ethylacetate 1.36 20 % Aqua-0.89 Fert Ethanol Alc Gly Product Category: Solvents Product Category: Alcohols, Ammonia Chlorinated (Sol Chl) Glycols & Water Mixes Thereof

    (Alc Gly) Xylene 0.89 Sol Gen Isopropyl Alc Gly Typical Reference Typical Reference

    Products Viscosity* (60 F) Products Viscosity* (60 F) 6 Oil (#5, #6) 0.9 FL&O Butanol Alc Gly Centipoise (cP) Centipoise (cP) Fuel Oil (#1, 0.9 FL&O Isobutyl Alc Gly Methylene-0.46 Methanol 0.64 #2, #3, #4) Chloride

    SAE Grades 0.9 FL&O Ethylene glycol Alc Gly Trichloro-0.6 Ethanol 1.29

    Ethylene

    Corn Oil 0.91 FL&O Propylene glycol Alc Gly Carbon Tetra-0.99 Isopropyl 2.78

    Chloride

    Cooking Oils 0.92 FL&O Demineralized Water Perchloro-1 Butanol 3.34

    Ethylene

    Olive Oil 0.92 FL&O Deionized Water Product Category: Alcohols, Glycols Isobutyl 4.54

    & Water Mixes Thereof (Alc Gly)

    Vegetable Oil 0.92 FL&O Asphalt Heated Ethylene glycol 25.5 Typical Reference

    Products Viscosity* (60 ?F)

    Acetates 0.93 Sol Gen Bunker C Heated Propylene glycol 54 Centipoise (cP)

    Soy Oil 0.93 FL&O Test D To obtain coverage for a product Methanol 0.64 Compressed liquids: Fuels and

    category: Test with one product in the Refrigerants, NH 3

    product category. The Certificate of Typical Reference

    Conformance will cover all products in the Products Viscosity*

    category. (60 ?F)

    Centipoise (cP) Sunflower Oil 0.93 FL&O Ethanol 1.29 Propane 0.098

    Anhydrous 0.188

    Ammonia

    NTEP - B35

NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

     Isopropyl 2.78 Butane 0.19 Ethylacetate 0.96 Sol Gen

    Bunker Oil 0.99 FL&O Butanol 3.34 Freon 11 0.313 Beverages 1.0 Water Tap water Water Isobutyl 4.54 Freon 12 0.359 Deionized 1.0 Water Potable Water Ethylene glycol 25.5 Freon 22 1.99 Demineralized 1.0 Water Nonpotable Water Propylene glycol 54 Ethane Juices 1.0 Water Juices Water Product Category: Clear Liquid Test A The following products must

    Fertilizers (Liq Fert) be individually tested and noted on

    the Certificate of Conformance. Milk 1.0 Water Beverages Water Typical Reference

    Products Viscosity*

    (60 ?F)

    Nonpotable 1.0 Water Water mixes of Alc Gly Centipoise (cP) Typical Product alcohols & glycols Products Category Potable 1.0 Water Urea Fert Urea 1 Methylene-Sol Chl

    Chloride Tap Water 1.0 Water Ammonia Nitrate Fert Ammonia Nitrate 11.22 Trichloro-Sol Chl

    Ethylene Propylene 1.04 Alc Gly 10-34-0 Fert 10-34-0 48 Carbon Tetra-Sol Chl glycol Chloride Hydrochloric 1.1 Chem 20 % Aqua-Fert 20 % Aqua-1.1 to 1.3 Perchloro-Sol Chl Acid Ammonia Ammonia Ethylene Ethylene glycol 1.19 Alc Gly Chlear Liquid Fert Fert Chlear Liquid Fert 31 to 110 Urea Liq Fert Liquid 1.25 Liq Feed Nitrogen Solution Fert Nitrogen Solution 31 to 110 Ammonia Nitrate Liq Fert Molasses

    9-18-9 1.32 Fert 28 %, 30 % or 32 % Fert 28 %, 30 % or 32 % 31 to 110 10-34-0 Liq Fert Methylene-1.34 Sol Chl N-P-K solutions Fert N-P-K solutions 20% Aqua-Liq Fert Chloride Ammonia 10-34-0 1.39 Fert 9-18-0 Fert 9-18-0 Chlear Liquid Liq Fert

    Fert Trichloro-1.47 Sol Chl 4-4-27 Sus Fert Product Category: Suspension Nitrogen Liq Fert Ethylene Fertilizers (Sus Fert) Solution Carbon Tetra-1.6 Sol Chl 3-10-30 Sus Fert Liq Fert Typical Reference 28 %, 30 % or Chloride Products Viscosity* 32 % (60 ?F)

    Perchloro-1.6 Sol Chl Molasses plus Phos Liq Feed N-P-K solutions Liq Fert Centipoise (cP) Ethylene Acid and/or Urea

    (TreaChle)

    NTEP - B36

    NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions

    Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

     Sulfuric Acid 1.83 Chem Liquid Molasses Liq Feed 4-4-27 20 to 215 9-18-0 Liq FertPhosphoric 1.87 Chem Sulfuric Acid Chem 3-10-30 100 to 1000 4-4-27 Sus Fert Acid

    Urea 1.89 Fert Phosphoric Acid Chem Product Category: Liquid Feeds (Liq 3-10-30 Sus Fert

    Feed)

    Bunker C 1.99 Heated Hydrochloric Acid Chem Molasses plus Liq Feed Typical Reference

    Phos Acid and/or Products Viscosity* (60 ?F)

    Urea (TreaChle) Fungicides 1 to 1.2 CC Herbicides CC-A Liquid Molasses Liq Feed Centipoise (cP) Micronutrients 1 to 1.2 CC Round-up CC-A Molasses plus 2882 Asphalt Heated

    Phos Acid and/or

    Urea (TreaChle)

    Molasses plus 1.1 to 1.3 Liq Feed Touchdown CC-A Liquid Molasses 8640 Bunker C Heated Phos Acid

    and/or Urea

    (TreaChle)

    3-10-30 0.9 to 1.65 Liq Fert Banvel CC-A Product Category: Heated Products Sulfuric Acid Chem

    (Heated)

    4-4-27 0.9 to 1.65 Liq Fert Treflan CC-A Phosphoric Acid Chem Typical Reference

    Products Viscosity* (60 ?F) Micronutrients 0.9 to 1.65 Liq Fert Paraquat CC-A Hydrochloric Chem Centipoise (cP)

    Acid 28%, 30% or 1.28 to 1.32 Fert Prowl CC-A Asphalt 100 to 5000 Herbicides CC-A 32%

    N-P-K 1.2 1.4 Fert Herbicides CC-A Bunker C 11,200 Round-up CC-A solutions

    Chlear Liquid 1.17 to 1.44 Fert Fungicides CC-B Product Category: Chemicals (Chem) Touchdown CC-A Fert

    Nitrogen 1.17 to 1.44 Fert Insecticides CC-B Treflan CC-A Typical Reference Solution Products Viscosity* (60 ?F) Test D To obtain coverage for each of the Adjuvants CC-B Banvel CC-A following product categories, test with one

    Fumigants CC-B Sulfuric Acid 1.49 Paraquat CC-A product in each product category. The

    Certificate of Conformance will cover all of Fungicides CC-C Phosphoric Acid 161 Prowl CC-A the products in the product category in which

    a product was tested.

    NTEP - B37

NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

    Micronutrients CC-D Hydrochloric Acid 0.80 to 1. 0 Herbicides CC-A Product Typical Specific

    Category Products Gravity*

    (60 F)

    Comp gas Compressed 0.6 to 0.8 Product Category: Crop Chemicals Fungicides CC-B

    Natural Gas (1=Air) (Type A) (CC-A)

    (CNG)

     Insecticides CC-B Typical Reference

    Products Viscosity* (60 ?F) Comp liq Anhydrous 0.61 Adjuvants CC-B Centipoise (cP) Ammonia

    Comp liq Butane 0.595 Herbicides 4 to 400 Fumigants CC-B Comp liq Ethane Round-up 4 to 400 Fungicides CC-C

    Comp liq Freon 11 1.49 Touchdown 4 to 400 Micronutrients CC-D Comp liq Freon 12 1.33 Banvel 4 to 400 Dual Flow Comp liq Freon 22 1.37 Treflan 4 to 400 Bicep Flow

     Paraquat 4 to 400 Marksman Flow Comp liq Propane 0.504 Prowl 4 to 400 Broadstrike Flow

     Product Category: Crop Chemicals Doubleplay Flow

    (Type B) (CC-B)

    Cryo LNG Liquefied Topnotch Flow Typical Reference

    Natural Gas Products Viscosity* (60 ?F) Cryo LNG Liquefied 0.66 Guardsman Flow Centipoise (cP)

    Oxygen

    Cryo LNG Nitrogen 0.31 Fungicides 0.7 to 100 Harness Flow

     Insecticides 0.7 to 100 NH3

     Adjuvants 0.7 to 100 Test D To obtain coverage for a

    product category: Test with one Fumigants 0.7 to 100

    product in the product category. The Product Category: Crop Chemicals Certificate of Conformance will cover (Type C) (CC-C) all products in the category.

     Tap Water Water Typical Reference

    Products Viscosity* (60 ?F)

     Deionized Water Centipoise (cP)

     Fungicides 20 to 900 Demineralized Water

    NTEP - B38

    NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions

    Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

     Product Category: Crop Chemicals Potable Water

    (Type D) (CC-D)

     Nonpotable WaterTypical Reference

    Products Viscosity* (60 ?F)

     Juices Water Centipoise (cP)

     Micronutrients 20 to 1000 Beverages Water

     Product Category: Flowables (Flow) Milk Water

     Liquefied Cryo LNG Typical Reference

    Oxygen Products Viscosity* (60 ?F)

     Nitrogen Cryo LNG Centipoise (cP)

     Dual 20 to 900 Liquefied Natural Cryo LNG

    Gas

     Bicep 20 to 900

     Marksman 20 to 900

     Broadstrike 20 to 900

     Doubleplay 20 to 900

     Topnotch 20 to 900

     Guardsman 20 to 900

     Harness 20 to 900

     Product Category: Compressed

    Liquids: Fuels and Refrigerants

    (Comp liq)

     Typical Reference Products Viscosity* (60 ?F)

     Centipoise (cP)

     Propane 0.098

     Anhydrous 0.188 Ammonia

     Butane 0.19

     Freon 11 0.313

     Freon 12 0.359

     Freon 22 1.99

     Ethane

    NTEP - B39

NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions Mass Meter Product Category & Test Magnetic Flow Meter Product Positive Displacement Flow Meter Turbine Flow Meter Product

    Requirements Category & Test Requirements Product Category & Test Category & Test Requirements

    Requirements

     Test D To obtain coverage for a

    product category: Test with one product

    in the product category. The Certificate

    of Conformance will cover all products

    in the category.

     Product Category: All Water (Water)

     Typical Reference

    Products Viscosity* (60 ?F)

     Centipoise (cP)

     Tap Water 1.0

     Deionized 1.0

     Demineralized 1.0

     Potable 1.0

     Nonpotable 1.0

     Juices 1.0

     Beverages 1.0

     Milk 1.0

     Test A The following products must

    be individually tested and noted on the

    Certificate of Conformance.

     Product Category: Cryogenic Liquids

    and Liquefied Natural Gas (Cryo LNG)

     Typical Reference

    Products Viscosity* (60 ?F)

     Centipoise (cP)

     Liquefied Oxygen 0.038

     Nitrogen 1.07

     Liquefied Natural

    Gas

    NTEP - B40

    NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions

    Product Family Table Category Abbreviations

    Abbreviation Product Categories

    FL&O Fuels, Lubricants, Industrial and Food Grade Liquid Oils

    Solv Gen Solvents General

    Solv Cl Solvents Chlorinated

    Alc Gly Alcohols, Glycols & Water Mixes thereof

    Water Water

    Fert Fertilizers

    CC-A Crop Chemicals (Type A)

    CC-B Crop Chemicals (Type B)

    CC-C Crop Chemicals (Type C)

    CC-D Crop Chemicals (Type D)

    Flow Flowables

    Sus Fert Suspension Fertilizers

    Liq Feed Liquid Feeds

    Chem Chemicals

    Heated Heated Products

    Comp liq Compressed Liquids: Fuels and Refrigerants NH 3

    Comp gas Compressed Gases

    Cryo LNG Cryogenic Liquids and Liquefied Natural Gas

     1Note: The Typical Products listed in this table are not limiting or all-inclusive; there may be other products and product trade names, which fall into a product family. Water

    and a product such as stoddard solvent or mineral spirits may be used as test products in the fuels, lubricants, industrial, and food- grade liquid oils product family.

     2 The specific gravity of a liquid is the ratio of its density to that of water at standard conditions, usually 4 ?C (or 40 ?F) and 1 atm. The density of water at standard conditions is 33approximately 1000 kg/m (or 998 kg/m)

     3 Diesel fuel blends (biodiesel) with up to 20 % vegetable or animal fat/oil.

     4 Gasoline includes oxygenated fuel blends with up to 15 % oxygenate.

     Centipoise

     Centistokes = ---------------------

     Specific Gravity 5 Kinematic viscosity is measured in centistokes.

    Source for some of the viscosity value information is in the Industry Canada - Measurement Canada Liquid Products Group, Bulletin V-16-E (rev. 1), August 3, 1999.

    NTEP - B41

NTEP Committee 2010 Interim Report

    Appendix B NTETC Measuring Sector - Appendix C Proposed NCWM Pub 14 Policy Revisions

    THIS PAGE INTENTIONALLY LEFT BLANK

    NTEP - B42

Report this document

For any questions or suggestions please email