MASTERSPEC

    SPECIFICATION

    CONCRETE DECK/GREEN ROOF (REINFORCED)

    SECTION 07123-A COLD FLUID-APPLIED WATERPROOFING (WITH FABRIC REINFORCEMENT) SYSTEM III PLUS

    PART 1 GENERAL

    1.1 RELATED DOCUMENTS

    A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

    Specification Sections, apply to this Section.

    1.2 SUMMARY

A. This Section includes the following:

    1. Surface preparation and substrate treatment.

    2. Waterproofing membrane.

    3. Sheet flashing and accessories.

    4. Protection course.

    5. Drainage panels.

    6. Insulation board.

    7. Geotextile filter fabric.

    B. Related Sections: The following Sections contain requirements that relate to this Section:

    1. Division 3 Section “Cast-in-Place Concrete” for concrete placement, curing, and finishing or “Pre-cast Concrete”

    casting and placement.

    2. Division 5 Section “Expansion Joint Cover Assemblies”, for expansion-joint cover assemblies and installation.

    3. Division 7 Section “Joint Sealant” for joint sealant materials and installation.

    1.3 PERFORMANCE REQUIREMENTS

    A. General: Provide a waterproofing system that prevents the passage of liquid water under hydrostatic pressure and

    complies with physical requirements as demonstrated by testing performed by an independent testing agency of

    manufacturer’s current waterproofing formulations and system design.

    1.4 SUBMITTALS

    A. Submit Product Data for each type of waterproofing specified, including manufacturer’s printed instructions for

    evaluating, preparing, and treating the substrate, technical data, and tested physical and performance properties.

    B. Project Data - Submit Shop Drawings showing locations and extent of waterproofing, including details for substrate

    joints and cracks, sheet flashing, penetrations, and other termination conditions.

C. Samples Submit representative samples of the following for approval:

    1. Waterproof membrane material.

    2. Protection course material.

    3. Prefabricated drainage panel.

    4. Geo-textile filter fabric.

    5. Insulation board.

    D. Installer Certificates Submit certificates signed by manufacturer certifying that Installers comply with requirements

    under the “Quality Assurance” Article.

    1.5 QUALITY ASSURANCE

    A. Installer Qualifications: Engage an experienced Installer who is certified in writing and approved by waterproofing

    manufacturer EPRO Services, Inc. for the installation of the SYSTEM III Plus Waterproofing System.

    B. Manufacturer Qualification: Obtain waterproofing materials and system components from a single manufacturer EPRO

    Services, Inc.

    C. Field Sample: Apply waterproofing system field sample to 100 sq./ft. (9.3 sq./m.) of deck or wall to demonstrate surface

    preparation, joint and crack treatment, thickness, texture, and standard of workmanship.

    1. Notify Architect one week in advance of the dates and times when field sample will be prepared.

    2. If Architect determines that field sample, does not meet requirements; reapply waterproofing until field sample is

    approved.

    3. Retain and maintain approved field sample during construction in an undisturbed condition as a standard for

    judging the completed waterproofing. An undamaged field sample may become part of the completed Work.

    D. Pre-installation Conference: A pre-installation conference shall be held prior to application of the waterproofing system

    to assure proper substrate and installation conditions, to include contractor, applicator, architect/engineer and special

    inspector (if any).

    1.6 DELIVERY, STORAGE, AND HANDLING

    A. Deliver materials to Project site as specified by manufacturer labeled with manufacturer’s name, product brand name

    and type, date of manufacture, shelf life, and directions for storing and mixing with other components.

    B. Store materials as specified by the waterproofing manufacturer in a clean, dry, protected location and within the

    temperature range required by waterproofing manufacturer. Protect stored materials from direct sunlight.

C. Remove and replace material that cannot be applied within its stated shelf life.

    1.7 PROJECT CONDITIONS

    A. Protect all adjacent areas not to be waterproofed. Where necessary, apply masking to prevent staining of surfaces to

    remain exposed wherever membrane abuts to other finish surfaces.

B. Perform work only when existing and for-cast weather conditions are within manufacturer’s recommendations for the

    material and application method used.

    C. Minimum clearance of 24 inches is required for application of product. For areas with less than 24-inch clearance, the

    product may be applied by hand using ECOLINE-R.

    D. All plumbing, electrical, mechanical and structural items to be under or passing through the waterproof membrane shall

    be positively secured in their proper positions and appropriately protected prior to membrane application.

    E. Waterproof membrane shall be installed before placement of reinforcing steel. When not possible, all exposed

    reinforcing steel shall be masked by General Contractor prior to membrane application.

    1.8 WARRANTY

    A. General Warranty: The special warranty specified in this Article shall not deprive the Owner of other rights the Owner

    may have under other provisions of the Contract Documents, and shall be in addition to, and run concurrent with, other

    warranties made by the Contractor under requirements of the Contract Documents.

    B. Special Warranty: Submit a written warranty signed by waterproofing manufacturer and Installer agreeing to repair or

    replace waterproofing that does not meet requirements or that does not remain watertight within the specified warranty

    period. Warranty does not include failure of waterproofing due to failure of substrate prepared and treated according to

    requirements or formation of new joints and cracks in substrate that exceed 1/16 inch (1.6 mm) in width.

    1. Warranty Period: 5-years after date of Substantial Completion.

    PART 2 PRODUCTS

    2.1 MANUFACTURERS

A. SYSTEM III Plus; EPRO Services, Inc., Wichita, KS, 800-882-1896

    1. Spray-Applied ECOLINE-S or roller-applied ECOLINE-R.

    2. Protection course ECOSHIELD-E10 or ECOSHIELD-E15.

    3. Drainage mat ECODRAIN-M20 (perforated) or ECODRAIN-S9000.

    2.2 WATERPROOFING MATERIALS

    A. Fluid applied waterproofing system ECOLINE-S: a single course, high build, polymer modified, asphalt emulsion.

    Waterborne and spray applied at ambient temperatures. Non-toxic and odorless. ECOLINE-R has similar properties

    with greater viscosity and is roller or brush applied. Manufactured by EPRO Services, Inc.

B. Fluid applied waterproofing physical properties.

    ECOLINE-S TYPICAL CURED PROPERTIES (MEMBRANE ONLY)

    TYPICAL UNCURED PROPERTIES

    Specific GravityASTM D 2441ViscosityASTM D 1200> 25 centipoisePH12.3FlammabilityASTM D 3143500? FColorBrown to BlackNon-ToxicNo SolventsShelf Life6 monthsTYPICAL CURED PROPERTIESInitial CureFinal Cure *Tensile StrengthASTM 41232 psiElongationASTM 4124140%Resistance To DecayASTM E 154 Section 134% Perm LossAccelerated AgingASTM G 23No EffectMoisture Vapor TransmissionASTM E 960.026 g/sq. ft. /hr.Hydrostatic Water PressureASTM D 75126 psi0.21Perm Rating (US PERMS)ASTM E 96 (US Persm)0Methane Transmission RateASTM D 1434Adhesion To Concrete & MasonryASTM C 836 & ASTM C 70411 lbf./inch80HardnessASTM C 836ASTM C 836No CrackingCrack BridgingASTM C 836-00No Cracking @ -20? CLow Temp. FlexibilityResistance To Acids:30%Acetic13%Sulfuric and Hydrochloric*See curings, protection and cleaning

    sections for further explanation.

    ECOLINE-R TYPICAL CURED PROPERTIES

    TYPICAL UNCURED PROPERTIES

    Specific GravityASTM D 2441ViscosityASTM D 1200> 25 centipoisePH12.3FlammabilityASTM D 3143500? FColorBrown to BlackNon-ToxicNo SolventsShelf Life6 monthsTYPICAL CURED PROPERTIESInitial CureFinal Cure *Tensile StrengthASTM 41232 psiElongationASTM 4124140%Resistance To DecayASTM E 154 Section 134% Perm LossAccelerated AgingASTM G 23No EffectMoisture Vapor TransmissionASTM E 960.026 g/sq. ft. /hr.Hydrostatic Water PressureASTM D 75126 psi0.21Perm Rating (US PERMS)ASTM E 96 (US Persm)0Methane Transmission RateASTM D 1434Adhesion To Concrete & MasonryASTM C 836 & ASTM C 70411 lbf./inch80HardnessASTM C 836ASTM C 836No CrackingCrack BridgingASTM C 836-00No Cracking @ -20? CLow Temp. FlexibilityResistance To Acids:30%Acetic13%Sulfuric and Hydrochloric*See curings, protection and cleaning

    sections for further explanation.

    2.3 AUXILIARY MATERIALS

    A. Sheet Flashing: 60-mil reinforced modified asphalt sheet good with double-sided adhesive.

    B. Reinforcing Strip: Manufacturer’s recommended polypropylene and polyester fabric.

    C. Joint Detailing Sealant Mastic: ECOLINE-R, a high viscosity polymer modified water based asphalt material.

    1. Back Rod: Closed-cell polyethylene foam.

    2. Single component urethane sealant.

    2.4 PROTECTION COURSE

    A. Protection Course Usage-ECOSHIELD-E15

    B. ECOSHIELD physical properties.

    Ecoshield-E Properties

    15-mil

    Puncture ResistanceASTM D 17091898 g.

    Tensile StrengthASTM E 15439.7 lbs. MD

    Tear ResistanceASTM D 45338.74 lbs.

    Low Temperature ImpactASTM D 1790Resistant to -105 C

    Water Vapor Trans. RateASTM E 96.00585 g./ft./hr.

    Perm RatingASTM E 960.0123

    Chemical or Environmental ResistanceExcellent

    Methane Gas ModifiedASTM D 14340

    2.5 MOLDED-SHEET DRAINAGE PANEL

A. For extensive roof design.

1. ECODRAIN-M20 a HDPE composite drainage panel, 3-diminsional, non-biodegradable with a permeable geo-

    textile heat bonded to drainage core.

2. ECODRAIN-M20 Specification Table.

    ECODRAIN-M20 Physical Properties

    ColorBrown

    Compressive Yield Strength ASTM D 162118,000 psf

    Grab TensileASTM D 4632130 lbs.

    Trapezoidal TearASTM D 453360 lbs.

    Puncture Strength ASTM D 483340 lbs.

    Water Flow ASTM D 4491158 gal/min

    B. For non-planting applications with free flow drainage.

1. ECODRAIN-S9000, a polystyrene composite drainage panel, 3-diminsional, non-biodegradable with a permeable

    geo-textile heat bonded to drainage core.

2. ECODRAIN-S9000 Specification Table.

    ColorBlack

    Compressive Yield Strength ASTM D 162118,000 psf

    Grab TensileASTM D 4632365 lbs.

    Trapezoidal TearASTM D 4533115 lbs.

    Puncture Strength ASTM D 4833105 lbs.

    AOS Typical ASTM D 475140 sieve size

    Water Flow (V) ASTM D 471621 gal/min./sq./ ft.

    Water Flow ASTM D 4491100 gal/min./sq./ft.

    2.6 FILTER FABRIC

    2.7 INSULATION BOARD

    PART 3 EXECUTION

    3.1 EXAMINATION

    A. Examine substrates, areas, and conditions under which waterproofing systems will be applied, with Installer present, for

    compliance with requirements. Do not proceed with installation until unsatisfactory conditions have been corrected.

    3.2 SURFACE PREPARATION

A. Clean and prepare substrate according to manufacturer’s recommendations. Provide clean, dust-free, and dry substrate

    for waterproofing application.

    B. Mask off adjoining surfaces not receiving waterproofing to prevent spillage or over spray affecting other construction.

    C. Close off deck drains and other deck penetrations to prevent spillage and migration of waterproofing fluids.

    D. Remove grease, oil, form release agents, paints, and other penetrating contaminants from concrete.

    E. Remove fins, ridges, and other projections and fill honeycomb, aggregate pockets, grout joints, tie holes, and other

    voids with ECOLINE-R, hydraulic cement, or rapid-set grout.

    3.3 PREPARATION AND TREATMENT AT TERMINATIONS AND PENETRATIONS

    A. Prepare vertical and horizontal surfaces at 90-degree terminations, at penetrations through waterproofing material, and

    at expansion joints, drains, and sleeves according to ASTM C 898 and manufacturer’s recommendations.

    B. Apply two coats of ECOLINE-R (30 mil each) and embed a joint reinforcing strip in preparation coat and apply a

    second coat over embedded joint reinforcing strip ensuring its complete saturation and covering.

    1. Terminations should be treated 3 inches on each side for both vertical and horizontal.

    2. Penetrations should be treated in a 3 inch radius around penetration and 3 inches onto penetrating object.

    3. Penetrations should be additionally fastened with polypropylene zip tie or other suitable clamp.

    3.4 PREPARATIONS AND TREATMENT OF JOINTS AND CRACKS

    A. Prepare, treat, rout, and fill joints and cracks in substrate according to ASTM C 898 and waterproofing manufacturer’s

    recommendations. Remove dust and dirt from joints and cracks complying with ASTM D 4258 prior to coating

    surfaces.

    B. Less than 1/16 in. - Apply two coats of ECOLINE-R waterproofing, 6 inches on each side of joint or crack and embed a

    joint reinforcing strip in preparation coat and apply a second coat over embedded joint reinforcing strip ensuring to

    complete saturation and covering.

    C. Greater then 1/16 in. Rout joint or crack, install backer-rod and sealant to bring flush to surface. Apply a coat of

    ECOLINE-R to joint or crack, 6 in. on each side, embed a joint reinforcement strip and apply a second coat, where

    indicated or required according to waterproofing manufacturer’s recommendations.

    3.5 WATERPROOFING APPLICATION

A. Set up spray equipment according to manufacturer’s instructions if spray-applying material.

B. Mix materials according to manufacturer’s instructions.

C. Start installing waterproofing in presence of manufacturer’s technical representative.

D. Apply waterproofing, according to manufacturer’s recommendations, by spray (ECOLINE-S) or roller (ECOLINE-R).

    E. Apply a base spray coat of ECOLINE-S or three 27 mil (wet) coats of ECOLINE-R, to obtain a seamless membrane

    free of entrapped gases, with an average dry film thickness of 60 mils (1.5 mm) and a minimum dry film thickness of 50

    mils (1.25 mm) at any point.

    F. Apply waterproofing to prepared wall terminations and vertical surfaces to heights indicated according to

    manufacturer’s recommendations and details.

G. Lay 3’ wide, polyester on and into the base coat of the membrane overlapping it 3’ (a light tack coat of ECOLINE-R or

    ECOLINE-S may be used around the edges of the polyester to temporarily hold it in place).

    H. Apply a second spray coat of ECOLINE-S or three 27-mil (wet) coats of ECOLINE-R to obtain a composite reinforced

    membrane with average dry film thickness of 120 mils and a nominal thickness of 100 mils.

I. Verify film thickness of waterproofing every 100 sq./ft. (9.3 sq./m).

     3.6 PROTECTION COURSE/ROOT BARRIER INSTALLATION

    A. Install ECOSHIELD-E15 protection course with overlapped seams over nominally cured membrane no later than

    recommended by manufacturer and before starting subsequent construction operations.

    3.7 INSULATION INSTALLATION

    A. Place insulation board meeting project requirements for R value compression strength and water absorption over

    protection course/root barrier with edges tightly abutted.

    3.8 DRAINAGE PANEL INSTALLATION

    A. Place and secure drainage panels to substrate according to manufacturer’s written instructions. Use adhesives and

    adhesive strips (sheet flashing that does not penetrate waterproofing) as recommended by manufacturer. Overlap edges

    of dimpled core and ends of geo-textile to maintain continuity. Protect installed panels during subsequent construction.

    3.9 FIELD QUALITY CONTROL

    A. Membrane may be checked for coverage with a lightly oiled, needle nose depth gauge, taking four (4) readings over a

    one square inch area, every 500 square feet. Record the minimum reading. Mark the test area for repair.

    B. Test areas are to be patched over with ECOLINE-S to an 80-mil minimum dry thickness, extending a minimum of one-

    inch (1”) beyond the test perimeter.

    C. Water test may be performed after installation of ECOLINE-S reinforced membrane and prior to the placement of the

    ECOSHIELD-E15 protection course. Perform test by ponding water at a minimum depth of 2-inches for a period of 48-

    hours.

    3.10 CURING, PROTECTING, AND CLEANING

    A. Cure waterproofing according to manufacturer’s recommendations. It should be noted normal curing time is 24 to 48

    hours to achieve a permanent water barrier. However, in some conditions such as a saturated substrate, extremely cold

    temperatures and/or high humidity, the full adhesion of the membrane may be delayed. The length of the delay is

    subject to the membrane and severity of those conditions.

    B. Take care to prevent contamination and damage during application stages, curing and subsequent construction.

    C. Clean spillage and soiling from adjacent construction using cleaning agents and procedures recommended by

    manufacturer of affected construction.