DOC

Message Low Range, Service Required in multifunction display and fault code 2942 andor 2943 stored in transfer case control unit

By Alan Alexander,2014-10-31 22:23
6 views 0
Message Low Range, Service Required in multifunction display and fault code 2942 andor 2943 stored in transfer case control unit

    Message "Low Range, Service Required" in multifunction display and fault code 2942 and/or 2943 stored in transfer case

    control unit. -

    主题编号 GI28.19-P-041403

    版本 1

    设计组 28.19 Transfer case - electrical system

    日期 08-13-2007

    有效性 Model 164 with Off-Road Pro engineering package (code 430)

    更改原因

投诉

    Message "Low Range, Service Required" in multifunction display and fault code 2942 and/or 2943 stored in transfer case control unit (N15/7).

原因

    Widened pins in cable-end connector of transfer case switchover magnet (Y108).

补救

    Note: Do not replace the transfer case switchover magnet (Y108)! 1.) Carefully unplug cable-end connector from transfer case switchover magnet (Y108).

    2.) Carefully open connector and unpin individual wires. Document: AR00.19-p-0120-26A (Remove contact from mini spade-type contact connector)

    Note: The widened female contacts must not be repaired as they are already irreparably damaged!

    3.) Cut the contacts from the lines immediately behind the crimp and fit new contacts on the lines.

    Note: Always replace both female contacts.

    Document: ar00.19-p-0100-04a (Repair wiring harness by crimping - watertight connections)

    Document: ws00.19-p-0002-10b (220 589 019984 Crimping set MLK 1.2 ELA)

    4.) Carefully assemble connector.

    Note: Observe pin assignment: 1=>gray/black; 2=>white 5.) Plug connector into transfer case switchover magnet (Y108) and check it is

    properly engaged.

    6.) Erase fault memory in transfer case control unit (N15/7). Note: Route the lines so that they are not stretched. 7.) Under "Control unit adaptations" perform calibration of the transfer case.

WIS 参考

    文档编号 标题 提示

    ar00.19-p-0100-04a Repair wiring harness by Repair wiring harness by

     crimping - watertight crimping - watertight

    connections connections

    ws00.19-p-0002-10b 220 589 019984 220 589 019984

     Crimping set MLK 1.2 Crimping set MLK 1.2

    ELA ELA

    AR00.19-p-0120-26A Remove contact from Remove contact from

     mini spade-type contact mini spade-type contact

    connector connector

症状

    症状

    Power transmission / Transfer case / Transfer case - function / Does not shift (low range)

    Power transmission / Transfer case / Transfer case - function / Differential lock nonfunctional

    Power transmission / Transfer case / Transfer case - function / Electrical fault/Fault code

控制单元/故障代码

    故障控制单元 故障代码说明 代码

    VG-Transfer 2943 The line from component N15/7 (Transfer case control case (VG1) module) (pin 12) to component Y108 (Transfer case

    switchover magnet) (pin 1) and (or) the line from

    component N15/7 (Transfer case control module) (pin

    9) to component Y108 (Transfer case switchover

    magnet) (pin 2) have an open circuit or short circuit to

    positive.

    VG-Transfer 2942 The line from component N15/7 (Transfer case control case (VG1) module) (pin 12) to component Y108 (Transfer case

    switchover magnet) (pin 1) and (or) the line from

    component N15/7 (Transfer case control module) (pin

    9) to component Y108 (Transfer case switchover

    magnet) (pin 2) have an open circuit or short circuit to

    ground.

零件

    

    零件号 名称 提示 ES1 ES2 EPC

    

    A 019 545 18 Female 2 Always replace all

    26 contact three female X

    contacts.

    A1695430231 Line 2 Available by the

    meter:

    Note: The repaired X line must have an

    overall length of

    220mm!

    A 000 545 84 Single-wire 2 ELA X 80 seal

操作号/损坏代码

    操作号 时间 损坏代码 提示

    操作内容

     5105058

Report this document

For any questions or suggestions please email
cust-service@docsford.com