Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential

Page 1

Unilink Team of R&D Department

    Unified Communications Holdings Limited (Shenzhen Office) http://www.unifiedcomms.com Revision Sheet

    Revision Date Author Remark

    1.0.0 2004-7-27 HuangXinguo None

    

    ,,

    HTTPEKK>@?44,

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential

    Page 2

     TABLE OF CONTENTS 1 INTRODUCTION OF

    DOCUMENT .............................................................................................. 3 1.1 Purpose ........................................................................................................................ 3 1.2

    Audience ....................................................................................................................... 4 1.3

    Scope ............................................................................................................................ 4 1.4

    Document Convention .................................................................................................. 4 2 INTRODUCTION OF

    SYSTEM .................................................................................................... 5 2.1 CFController

     RouteServer ....................................................................................... 5 2.2 RouteServer

    CFController ....................................................................................... 9 Clt-alt-3 for Sub Header

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential Page 3 2.3 Broadcast Message ........................................................................ 错误

    错误错误

    错误?

    ??

?未定义书签

    未定义书签未定义书签 未定义书签。

    。。

    

     1 Introduction of Document 1.1 Purpose The purpose of this document is to provide detailed information about how to install and

    configure the Unilink (Unilink Intelligence Switching Platform). With this document, users can setup total system, make system run normally, and handle some problems during running. Trouble Shooting will provide some help for users. ?常用网络设备的调

    测命令;;A1?y#?go

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential Page 4 1.2 Audience Support Engineer and Engineer of customer will use this document to complete their

    work. 1.3 Scope This document is divided into three parts, they are “Installation”,

    “Configuration” and

    Adjustment and Trouble Shooting”.

    Installation part will describe how to install Unilink system. Using the CD-ROM of Unilink or the packet downloaded from Web, user can install them into themselves environment.

    Configuration part will describe how to configure modules. Main part of this is configuration file of modules.

    Trouble shooting part will describe how to solve those problems appearing during running and configuration and so on. 1.4 Document Convention The Document contains a list of functional requirements that are tagged by section and

    sub-section numbers. One requirement may to another requirements with reference to the sub-section number of the requirement.

    In order to enable automatic formatting and update of cross-reference, the following

short-cut keys are defined in the document template:

    Clt-alt-1 for Header Clt-alt-2 for Sub Header

    Clt-alt-3 for Sub Header nt>>>>>>>>>>>>>>>>

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential Page 5 2 Introduction of System

    There are several points as protocol part, list as following:

     When SM connects to CFC, CFC should send an initialization message to SM.

     An initialization operation includes two messages: 0x109, 0x113.

     During initialization, there may are many message 0x109, but just one message 0x113.

     Message 0x109 and 0x113 is served as initialization one transaction, so any other message should not be inserted them.

     Last message 0x109 is indicated by status, CFC should set the status in header of package to 1.

     None limited is about the sequence of messages 0x109.

     Max logical span is 1500

     To compatible back, the sequence of keys in message must go by this document.

     SystemMonitor should alarm when it receive any a message who is out of the initialization range.

     SystemMonitor should clear Inbound occupy counter and Outbound occupy

    counter”; update “Inbound line counter” and “Outbound lines counter”; All of

    channels are set to “Idle”.

     2.1 CFController

     SystemMontior There are five messages sent to SystemMonitor by CFController, they are: Initialize Property Info:

    Message Type Number of Pair Direction Remark

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential

    Page 6 0x109 0x05 CFC

    SM Initialize Property Info

    Pair Key Pair Type Pair Size Remark 0x01 0x01 0x01 Physical Slot Number 0x02 0x02 0x02 Physical Span Number 0x03 0x02 0x02 Logical Span Number 0x04 0x03 0x04 Channel I/O Info

    (32 bits, each bit indicate one

    channel i/o type info: 0=in,

    1=out)

    0x05 0x03 0x04 Channels Status Info (32Bits, each bit indicate one

    channel status info: 0=block,

    1=idle)

Initialize Total Lines Info:

    Message Type Number of Pair Direction Remark 0x113 0x04 CFCSM Initialize Total Lines Info Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Inbound lines total count 0x02 0x02 0x02 Reserved

    0x03 0x02 0x02 Outbound lines total count 0x04 0x02 0x02 Reserved

Incoming (call control):

    Message Type Number of Pair Direction Remark 0x101 0x06 CFCSM Incoming (call control)

    Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span

    0x02 0x01 0x01 Channel

    0x03 0x04 Variable Caller part number 0x04 0x04 Variable Called part number 0x05 0x01 0x01 Caller part category 0x06 0x04 Variable Description info for Signaling

Outgoing (call control):

    Message Type Number of Pair Direction Remark 0x102 0x09 CFCSM Outgoing (call control)

    Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span of inbound

    0x02 0x01 0x01 Channel of inbound

    0x03 0x01 0x01 Node ID of outbound

    0x04 0x02 0x02 Span of outbound

    0x05 0x01 0x01 Channel of outbound

    0x06 0x04 Variable Caller part number 0x07 0x04 Variable Called part number

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential

    Page 7 0x08 0x01 0x01 Caller part category 0x09 0x04 Variable Description Info for signaling

Connect (call control):

    Message Type Number of Pair Direction Remark

    0x103 0x05 CFCSM Connect (call control) Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span of inbound 0x02 0x01 0x01 Channel of inbound 0x03 0x01 0x01 Node ID of outbound 0x04 0x02 0x02 Span of outbound 0x05 0x01 0x01 Channel of outbound

Release (call control):

    Message Type Number of Pair Direction Remark

    0x104 0x02 CFCSM Release (call control) Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span

    0x02 0x01 0x01 Channel

Block (call control):

    Message Type Number of Pair Direction Remark

    0x105 0x03 CFCSM Block (call control) Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span

    0x02 0x01 0x01 Channel

    0x03 0x02 0x02 Cause Value

Unblock (call control):

    Message Type Number of Pair Direction Remark 0x110 0x02 CFCSM Unblock (call control)

    Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span

    0x02 0x01 0x01 Channel

    Report Call flow Progress (call trace): Message Type Number of Pair Direction Remark 0x108 0x05 CFCSM Report call flow progress (call trace)

    Pair Key Pair Type Pair Size Remark 0x01 0x04 Variable Caller part number 0x02 0x02 0x02 Span of inbound

    0x03 0x01 0x01 Channel of inbound

    0x04 0x04 Variable Description for current progress ?

     Version 1.0.0 Communication Interface between CFC and SMonitor Strictly Confidential

    Page 8 0x05 0x02 0x02 Reserved

    Report Call Result (call statistic): Message Type Number of Pair Direction Remark 0x111 0x08 CFCSM Report call result (call statistic)

    Pair Key Pair Type Pair Size Remark 0x01 0x02 0x02 Span of inbound

    0x02 0x01 0x01 Channel of inbound