    DORMITORY AUTHORITY STATE OF NEW YORK

    CODE COMPLIANCE REVIEW

    Building Code of New York State

    Campus/Facility: Client: (Address)

    Building Name(s): Building Numbers: Project Title:

    Architect/Engineer:

    JDE # Estimated Project Cost:

    Code Enforcement Jurisdiction: DASNY Other: Variance Requested: Yes No Occupancy Classification(s): Construction Classification: Project Type: New Building Reconstruction Chapter 34 Compliance

    Check all that apply. Refer to Repair Change of Occupancy Alternatives. Provide

    Appendix K for definitions. Renovation Addition evaluation with this code

     Alteration Historic Building review. Work Involved: General Construction Structural Site Work Check all that apply. Roofing Mechanical Sprinkler

     Asbestos Abatement/Environmental Plumbing Elevators

     Fire Alarm Electrical Other

    LEGEND: NA: Not Applicable, NR: Not Required, NP: Not Permitted FC: Fire Code, PC: Plumbing Code, MC: Mechanical Code, FGC: Fuel Gas Code, ECCC: Energy Conservation Construction Code

    Building Code Required/ No Topic Actual Comment Section (unless Allowed otherwise noted)

     1 Fire Apparatus Access FC503.1

    Road

     2 Incidental Use Areas 302.1.1

     Attach analysis. 3 Mixed Occupancies: 302.3

     Nonseparated Uses 302.3.2

     Separated Uses (Ratio < 1) 302.3.3

     4 High Rise Buildings 403

     Sprinkler Protection 403.2

     Fire Alarm 403.5- 403.8

     Standby & Emergency 403.10-403.11

    Power

     5 Atriums 404

     Sprinkler Protection 404.3

     Smoke Control 404.4

     Enclosures 404.5

     Smoke Detection 404.6

     Travel Distance 404.9

     Provide additional information indicating number, 6 Control Areas 414.2 size, materials stored, and quantity of each material.

     Provide additional information below. 7 Building Area & Height 501

     8 Exterior Wall Fire-602.1

    Resistance Rating Table 602

     Exterior Fire Separation 602.1

    Distance Table 602

Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 1

    Required/No Topic Code Section Actual Comment Allowed

     9 Fire Resistive Construction 701.1

     Attach analysis. Exterior Wall: Allowable 704.8

    Area of Openings:

     Unprotected 704.8

     Protected 704.8

     Exterior Wall: Vertical 704.9

    Separation of Openings

     Parapets 704.11

     Fire Walls 705

     Fire Barriers 706

     Shaft Enclosures 707

     Fire Partitions 708

     Smoke Barriers 709

     Fire Stopping 711

     Joint Systems 712

     Opening Protectives 714

     Concealed Spaces 716

     10 Interior Finishes 801.1

     Wall & Ceiling: Exits 803.5

     Wall & Ceiling: Exit 803.5

    Access

     Wall & Ceiling: Rooms 803.5

     Floors 804

     11 Fire Protection: General 901.1

     Sprinkler System 903

     Alt. Fire Extinguishing 904

    System

     Standpipe System 905

     Portable Fire Extinguishers 906

     Fire Alarm System 907

     Smoke Detection System 907

     Emergency Voice 907

     Smoke Control 909

     Smokeproof Enclosure/ 909.20

    Stair Pressurization

     Fire Command Center 911

     Also provide additional information below. 12 Exits 1001.1

     Exit Lights 1003.2.10

     Emergency Lighting 1003.2.11

     Accessible Means of 1003.2.13

    Egress

     Area of Refuge 1003.2.13.5

     Access-Controlled Egress 1003.3.1.3.4

    Doors

     Interior Stairs 1003.3.3

     Handrails 1003.3.3.11

     Panic Hardware 1003.3.1.9

     Ramps 103.3.3.4

     Exit Doorway 1004.2.2

    Arrangement

     Common Path of Travel 1004.2.5

     Corridor Fire Rating 1004.3.2.1

     Corridor Width 1004.3.2.2

     Dead End Corridor 1004.3.2.3

    Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 2

    Required/No Topic Code Section Actual Comment Allowed

     Building with One Exit 1005.2.2

     Exit Fire Rating 1005.3.2

     Smokeproof Enclosure 1005.3.2.5

     Horizontal Exit 1005.3.5

     Exterior Stairs 1005.3.6

     Assembly 1008

     13 Accessibility 1101.1

    ICC/A117.1(98)

     Accessible Route 1104.1

     Accessible Entrance 1105.1

     Parking 1106.1

     Group R-2 1107.6.2

     Toilet Rooms 1109.2

     Signage 1110.1

     14 Ceiling Heights 1207.2

     15 Light: Natural/Artificial 1204

     Ventilation 1202

     Provide additional information below. 16 Energy Conservation 1301/ECCC

     17 Roof Assembly Fire 1505.1

    Classification

     Roof Covering 1507.1

     Provide additional information below. 18 Structural Requirements 1601.1

     Provide additional information below. 19 Foundation 1801.1

     20 Safety Glazing 2406.1

     21 Electrical 2701.1

     Emergency & Standby 2702.1

    Power

     Smoke Control Systems 2702.2.2

     Exit Signs 2702.2.3

     Means of Egress 2702.2.4

     Elevator 2702.2.5/2702.2.

    18

     High Rise Building 2702.2.14

     Smokeproof Enclosures 2702.2.19

     22 Mechanical Systems 2801.1

     Refer to 715.5 for specific requirements. Fire & Smoke Dampers 715.5

     Fan Shutdown MC606.4.1

     Provide additional information below. Combustion Air MC701.1 &

    FGC304.1

     Provide diameter of chimney/gasvents. Chimneys, Flues & MC801.1 &

    Gasvents FGC501.1

     23 Plumbing 2901.1

     Provide additional information below. Fixture Count 2902.1

     Maximum Consumption PC604.4

     Available Street Water

    Pressure

     Fixture Units PC709.1

     House Traps PC1002.6

     See Labor Law Art. 10-A for piping materials. Water Supply Materials Labor Law Art.

    10-A

     24 Elevator Emergency 3003.2

    Operation

     Elevator Hoistway Venting 3004

    Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 3

    Required/No Topic Code Section Actual Comment Allowed

ADDITIONAL INFORMATION:

    ALLOWABLE FLOOR AREA (503/506)

    STORY NO. BLDG AREA PER TABLE 503 AREA AREA FOR OPEN AREA FOR ALLOWABLE 1 STORY (ACTUAL) SPACE INCREASE SPRINKLER AREA 2INCREASE

    1 Open space area increases from Section 506.2 are computed thus:

    a. Perimeter which fronts a public way or open space having 20 feet minimum width = (F)

    b. Total Building Perimeter = (P)

    c. Ratio (F/P) = (F/P)

    d. W = Minimum width of public way = (W)

    e. Percent of frontage increase I = 100 [ F/P - 0.25] x W/30 = (%) f2 The sprinkler increase per Section 506.3 is as follows:

    a. Multi-story building I = 200 percent sb. Single story building I = 300 percent s

MAXIMUM BUILDING AREA? (503/506)

    ? Maximum Building Area = number of stories in the building x max allowable floor area (A) but not greater than 3 x A.

    ACTUAL: ALLOWABLE:

ALLOWABLE HEIGHT (503/504)

    ACTUAL ALLOWABLE INCREASE FOR SPRINKLERS (TABLE 503)

    Building Height in Feet Feet Feet = H + 20' =

    Building Height in Stories Stories + 1 =

    Stories

    Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 4

NUMBER AND ARRANGEMENT OF EXITS (1003/1004/1005)

    FLOOR, ROOM OR SPACE MINIMUM TRAVEL DISTANCE ARRANGEMENT MEANS OF EGRESS

    DESIGNATION NUMBER OF EXITS (1004.2.2)

    REQD ACTUAL ALLOWABLE ACTUAL REQUIRED ACTUAL

    DISTANCE DISTANCE

    BETWEEN EXIT SHOWN ON

    DOORS PLANS

OCCUPANT LOAD & EXIT WIDTH (1003)

    USE GROUP EXIT WIDTH (in) (a) (b) (c) (d) OR SPACE AREA OCCUPANT AREA PER EGRESS WIDTH REQUIRED ACTUAL WIDTH DESCRIPTION sq. ft. LOAD WIDTH PER OCCUPANT SHOWN ON OCCUPANT (ab) (TABLE PLANS (SECTION 1003.2.3) (TABLE 1003.2.3) c x d 1003.2.2.2)

    STAIR LEVEL STAIR LEVEL STAIR LEVEL

PLUMBING FIXTURE REQUIREMENTS (2902.1)

    OCCUPANCY WATERCLOSETS URINALS LAVATORIES SHOWERSDRINKING FOUNTAINS

    / TUBS MALE FEMALE MALE FEMALE REGULAR ACCESSIBLE

    Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 5

ENERGY CODE COMPLIANCE (Note: All code citations given are to the Energy Conservation Construction Code)

    COMPLIANCE METHOD

    Residential (101.3.1) Yes No If yes, indicate compliance method below:

    Energy Conservation Construction Code of New York State Check one chapter box & one glazing area box below:

    Chapter 4 One and two family dwelling with glazing area 15% ;15%

     Chapter 5 R-2, R-4 or Townhouse with glazing area 25% ;25%

     Chapter 6

    Commercial (101.3.2) Yes No If yes, indicate compliance method below:

    Energy Conservation Construction Code of New York State, Chapter 7

     Chapter 8

    EXEMPT BUILDING? (101.4.1) Yes No

     If yes, describe exemption type:

    HISTORIC BUILDING? (101.4.2.3) Yes No

    ALTERATION IN EXISTING BUILDING? (101.4.2.4) Yes No

     If yes, list building system(s) undergoing substantial alteration(s):

    PROJECT LOCATION: (302.1)

    County:

    Zone:

    THERMAL VALUES OF BUILDING COMPONENTS (104.3/402/502/503/602/802/803)

    Fill in values below as applicable:

    Foundation wall construction U-value: Foundation wall insulation R-value:

     Insulation depth:

    Below grade wall insulation R-value: Basement walls U value: Basement wall insulation R-value:

     Insulation depth:

    Crawl space walls U-value Crawl space wall insulation R-value: Heated slab on grade insulation R-value: Unheated slab on grade insulation R-value: Slab edge insulation R-value:

     Insulation depth:

    Floors over unheated spaces U-value: Floors over unheated spaces insulation R-value: Interior walls separating conditioned &

     unconditioned spaces insulation R-value: Exterior wall construction U-value: Exterior wall insulation R-value: Roof/ceiling construction U-value: Roof/ceiling insulation R-value: Skylights U-value: Windows U-value:

    Air infiltration rate:

    % window area:

    Projection factor:

    Exterior doors U-value:

     Air infiltration rate:

     % door area

    Fenestration solar heat gain coefficient:

Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 6

Duct insulation R-value:

    Pipe insulation R-value:

    MECHANICAL & ELECTRICAL SYSTEMS: (402/503/504/505/603/803/804/805/806)

    Electric resistance heat? (101.3.1.3) Yes No

    Renewable energy sources used? (403/806.2.4) Yes No

     If yes, describe type:

    Describe HVAC system(s) type:

Design Values:

     Heating Cooling

     Indoor temperature

     Outdoor temperature

    Heating and cooling load calculations: Attach calculations for all systems.

    Equipment:

    Fill in values below as applicable:

     Equipment Type Fuel Rating/Size Efficiency Type

     Water Heaters

     Storage Tanks

     Boilers Steam HW

     Furnaces

     Chillers Electric Centrifugal

    Air cooled

    Water cooled

     Condensers

     Cooling Towers

     Air Conditioners Air cooled

    Water cooled

     Heat Pumps Air cooled

    Water cooled

     Groundwater

    Ground source

     Package units Heating Cooling

     Unit heaters

     Transformers Liquid Dry

     Phase:

     Voltage: 2Lighting W/ft:

    Building:

    Tenant areas: (List all that apply)

    Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 7

STRUCTURAL DESIGN

    DESIGN LOADS:

    Importance Factors (1604.5): Wind (I): W

     Snow (I): S

     Seismic (I): E

    Live Loads (1607): Roof psf

     Floor psf

     Snow Load (1608): psf

    Wind Load (1609): Basic Wind Speed mph (ASCE-7-98)

     Exposure Category

SEISMIC REQUIREMENTS (1613 1623)

    Seismic Use Group

    Spectral Response Acceleration S %g S %g MSM1

    Seismic Design Category

    SEISMIC DESIGN CATEGORY A

    Compliance with Section 1616.4 only? Yes No

    SEISMIC DESIGN CATEGORY B, C, & D

    Provide the following Seismic Design Parameters:

    Basic structural system (check one)

     Bearing Wall Dual w/Special Moment Frame

     Building Frame Dual w/Intermediate R/C or Special Steel

     Moment Frame Inverted Pendulum

    Analysis Procedure Simplified Equivalent Lateral Force Modal

    Architectural, Mechanical, Components anchored?

    LATERAL DESIGN CONTROL: Earthquake:

     Wind:

FOUNDATIONS (1801.1)

    SOIL BEARING CAPACITIES:

    Field Test (provide copy of test report) psf

    Presumptive Bearing capacity psf

    Pile size, type, and capacity

COMBUSTION AIR (MC701.1 &FGC 304.1)

    HEATING APPLIANCE BTUH O. OF Q. IN. SQIN FREE AREA SQIN FREE AREA NBTUH/S

    INPUT OPENINGS 1000 2000 ROSS NET 4000 GGROSS

     Total (Sq. In.):

ADDITIONAL COMMENTS:

    Code Compliance Review: Building Code of New York State - Rev. 12/02.1 Page 8