Chapter 12 Operation Order and Installation(apm)

     Chapter 12 Operation Order and Installation

12 章运行顺序 和安装

12.1 运行顺序

    ?这里介绍位控情况下的运行顺序

     Start

     选择集电极开路或是线性驱动 Select pulse output type of positioning module.

    Fix positioning operation method and control unit 确定返回方法, 坐标, 运行模式, 控制单元 Install positioning software package to computer.

    Positioning data preparation by software package 软件包准备.

    ?Positioning parameter (X, Y, Z axis)

    ?Operation data (X, Y, Z axis)

    Install positioning module to the base.

    Positioning module,drive machine,motor, connection between external machine

    Drive Unit Ready signal, high/low limit signal, emergency stop

    signal should be ON in wiring.

    Cable connection between Computer and RS-232c port of CPU

    Power application to PLC system. CPU 模块是STOP.电源的使用 Positioning module system test 通过位控模块LED和软件核实连线状态 Setting data write by positioning module on PC 通过软件写入

    Positioning startup and various data setting/ change/monitoring 通过软件起动模式运行. ?Origin address setting 核实位控参数?位置数据?速度数据的设定是否正确并保存.必要时可

    ?positioning data setting (address) by teaching function, jog 改变

    operation, manual pulse generator.

    GMWIN or KGL-WIN Positioning program write

    Positioning operation by CPU module & positioning module

    End

    12 - 1

     Chapter 12 Operation Order and Installation

12.2 安装

12.2.1 安装环境

    在不考虑安装环境时?这个机器必须要有一个好的可靠性。但是以下几项必须注意才能保证整个系统

    的稳定性和安全性。

    1) 环境条件

    -安装防水?防振的控制面板

    - 没有持续的冲击和振动的地方.

    - 不要安放在直接暴露在光线的地方.

    - 不要安放在由于温度的迅速变化而产生雾气的地方.

    - 周围的环境温度在0-55?之间.

    2) 安装结构

    - 在处理螺孔和导线时?要注意不要将线头落入PLC 内部.

    - 安装在好操作的地方.

    - 别在同一面板上安装高压电器设备

    - 周边模块的距离要大于50mm.

    - 周边噪声环境要好.

12.2.2 操作时的注意事项

    这里介绍处理位控模块时要注意的几点注意事项

    1) 禁止跌落或重压.

    2) 别移动PCB板?否则会出现故障.

    3) 在连线时?注意不要将线头落入在模块板上?如有应立即清除

    4) 在电源为ON时?不允许拔插模块

12.3 配线

12.3.1 配线注意事项

    1) 位控模块和驱动设备之间的连线应尽可能的短. (最大长度 : 2m). 2) 对于交流电源和位控模块的外部I/O信号?需要单独分开的电缆以避免浪涌和交流电的信号干扰.

    3) 导线的选择因考虑周围的环境温度和使用电流?建议使用大于最大尺寸AWG22(0.3?). 4) 在连线时?如果太靠近高温设备和材料或是直接和油时间太长都可能会造成短路事故. 5) 在连接外部信号到端子板时要注意极性的是否正确.

    6) 将高压电缆和电源线一起走线时?由于感应可能会造成故障.

    7) 用管道进行连线时?管道接地是必要的.

    8) 从外部输入的电源 (DC 5V, DC24V),必须是安全稳定的电源.

    9)在连接位控模块和驱动设备时?要考虑噪声源的影响。因此?到电机驱动器的脉冲输出导线最好用双

    绞线和屏蔽线。

    12 - 2

     Chapter 12 Operation Order and Installation

12.3.2 伺服器和步进电机驱动设备连接实例

    1) MR-H?A 连接 (线性驱动)

    Reviva l option l Servo Motor N C P R U U Power MR-H;A V V S 3 AC200V SM W W T E R1 S1

     Detector CN2 Within 10m CN1 11 G4F-PP1/2/3D SG 40 SG High limit External EMG 46 EMG OV+ 25 Low limit Servo ON 12 SON OV- 26 External stop Reset 15 RES STOP 27 Approx. origin Torque limit 13 DOG 28 TL Normal limit VTP switching 38 LSP VTP 29 External comm. Within 50m Reverse limit LSN 39 ECMD 30 comm.. Jog reverse JOG- 31 VIS 20 DC24V 22 COM 32 VDD CR 37 17 SG CN3 FP+ 21 PP 10 Monitor output 10K 11 4 MO1 PPR FP- 22 NP 3 MO2 35 RP+ 23 NPR 1 MOG RP- 24 36 DRVIN 33 RD 49 Within 2m DRVIN COM 34 HOME +5V LZ 37 8 HOME COM 38 LZR 9 5V MPG A+ 1 Zero speed detection A MPG A- 2 VDD 21 RA1 B MPG B+ 3 ZSP 23 failure MPG B- 4 0V ALM 48 RA2 MPG External simultaneous start CON 7 Emergency stop EMG 8 DC24V COM 10 ZONE 1 11 P15R 1 ZONE 2 12 Analog torque limit command (+) TLAP 27 ZONE 3 13 +10V/max. current LG 28 ZONE COM 14 N15R 26 Analog torque limit command(-) 29 TLAN -10V/max. current LG 30 SD 50

     Within 2m

    12 - 3

     Chapter 12 Operation Order and Installation

    2) MR-J2/J2S-?A 连接 (线性驱动)

     (1) G4F-PP1/2/3D

    HC-MF HA-FF Series motor MR-J2S-;A NF MC U TE1 L1 U V 1 Power SM L2 V 3phase 200VAC W L3 W E L11 L21 PE EMG B1 CTE2 PE D B2 P 24VDC electronic brake OPP of Servo ON signal CN1A Within 10m Cutoff by alarm signal detector CN2 G4F-PP1/2/3D OPC 11 FP+ 21 PP 3 FP- 22 PG 13 RP+ 23 NP 2 RP- 24 NG 12 DRVIN 33 RD 19 DRVIN COM 34 COM 9 CR 8 SG 10 CN3 37 HOME +5V LZ 5 RD 12 TxD HOME COM 38 LZR 15 SD 2 RxD GND 1 LG Personal High limit OV+ 25 GND computer 11 LG Low limit OV- 26 LG 1 RS 5 LG External stop STOP 27 SD Plate CS 15 LG Approx. origin DOG 28 DR CN1E External EMG VTP switching VTP 29 EMG 15 ER External comm. Servo ON ECMD 30 SON 5 Reset Jog reverse JOG- 31 RES 14 Monitor output DC24V Proportional control COM 32 PC 8 4 GND A Torque limit Max. 10mA 10k TL 9 3 RS 5V *3 Normal limit MPG A+ 1 LSP 16 A CS 14 A Reverse limit 10k *3 MPG A- 2 LSN 17 DR 13 B MPG B+ 3 SG 10 Plate ER MPG B- 4 0V SG 20 Within 2m VDD 3 MPG COM 13 RA1 ALM 18 External Simultaneous start RA2 failure CON 7 ZSP 19 Emergency stop zero speed detection ENG 8 RA3 TLC 6 in torque limit DC24V COM 10 ZONE 1 11 P15R 11 Analog torque limit ZONE 2 12 TLA 12 +10V/max. current ZONE 3 13 LG 1 ZONE COM 14 SD Plate Within 2m

    12 - 4

     Chapter 12 Operation Order and Installation

    (2) G6F-PP1/2/3D

    HC-MF HA-FF Series motor MR-J2S-;A NF MC U TE1L1 U V 1 Power SM L2 V 3phase 200VAC W L3 W E L11 L21 PE EMG B1 CTE2 PE D B2 P 24VDC electronic brake OPP of Servo ON signal CN1A Within 10m Cutoff by alarm signal detector

    CN2 G6F-PP1/2/3D OPC 11 FP+ 21A PP 3 FP- 22A PG 13 RP+ 23A NP 2 RP- 24A NG 12 DRVIN 33A RD 19 DRVIN COM 34A COM 9 CR 8 SG 10 CN3 HOME +5V 37A LZ 5 RD TxD 12 HOME COM 36A LZR 15 SD RxD 2 GND 1 LG Personal High limit OV+ 25A GND computer LG 11 Low limit OV- 26A LG 1 RS LG 5 External stop STOP 27A SD Plate CS 15 LG Approx. origin DOG 28A DR CN1E External EMG VTP switching VTP 29A EMG 15 ER External comm. Servo ON ECMD 30A SON 5 Reset Jog reverse JOG- 31A RES 14 Monitor output DC24V Proportional control COM 32A PC 8 4 GND A Torque limit 10k Max. 10mA TL 9 RS 3 5V *3 Normal limit MPG A+ 1A A LSP 16 CS 14 A Reverse limit 10k *3 MPG A- 2A LSN 17 13 DR B MPG B+ 3A SG 10 Plate ER MPG B- 4A 0V SG 20 Within 2m VDD 3 MPG COM 13 RA1 External simultaneous start ALM 18 RA2 failure CON 7A ZSP 19 Emergency stop zero speed detection ENG 8A RA3 TLC 6 in torque limit DC24V COM 10A P15R 11 Analog torque limit TLA 12 +10V/max. current LG 1 SD Plate Within 2m

    12 - 5

     Chapter 12 Operation Order and Installation

    3) MR-J2/J2S-?A 连接 (集电极开路)

     (1) G4F-PP1/2/3O

    HC-MF HA-FF Series motor MR-J2S-;A NF MC U TE1 L1 U V 1 Power SM L2 V 3phase 200VAC W L3 W E L11 L21 PE EMG B1 CTE2 PE D B2 P 24VDC electronic brake OPP of Servo ON signal CN1A Within 10m Cutoff by alarm signal detector CN2 G4F-PP1/2/3O DC24V OPC 11 FP+ 21 PP 3 FP- 22 PG 13 RP+ 23 NP 2 RP- 24 NG 12 DRVIN 33 RD 19 DRVIN COM 34 COM 9 CR 8 SG 10 CN3 37 HOME +5V LZ 5 RD 12 TxD HOME COM 38 LZR 15 SD 2 RxD GND 1 LG Personal High limit OV+ 25 GND computer 11 LG Low limit OV- 26 LG 1 RS 5 LG External stop STOP 27 SD Plate CS 15 LG Approx. origin DOG 28 DR CN1E External EMG VTP switching VTP 29 EMG 15 ER External comm. Servo ON ECMD 30 SON 5 Reset Jog reverse JOG- 31 RES 14 Monitor output DC24V Proportional control COM 32 PC 8 4 GND A Torque limit Max. 10mA 10k TL 9 3 RS 5V *3 Normal limit MPG A+ 1 LSP 16 A CS 14 A Reverse limit 10k *3 MPG A- 2 LSN 17 DR 13 B MPG B+ 3 SG 10 Plate ER MPG B- 4 0V SG 20 Within 2m VDD 3 MPG COM 13 RA1 ALM 18 External Simultaneous start RA2 failure CON 7 ZSP 19 Emergency stop zero speed detection ENG 8 RA3 TLC 6 in torque limit DC24V COM 10 ZONE 1 11 P15R 11 Analog torque limit ZONE 2 12 TLA 12 +10V/max. current ZONE 3 13 LG 1 ZONE COM 14 SD Plate Within 2m

    12 - 6

     Chapter 12 Operation Order and Installation

    (2) G6F-PP1/2/3O

    HC-MF HA-FF Series motor MR-J2S-;A NF MC U TE1L1 U V 1 Power SM L2 V 3phase 200VAC W L3 W E L11 L21 PE EMG B1 CTE2 PE D B2 P 24VDC electronic brake OPP of Servo ON signal CN1A Within 10m Cutoff by alarm signal detector

    CN2 G6F-PP1/2/3O DC24V OPC 11 FP+ 21A PP 3 FP- 22A PG 13 RP+ 23A NP 2 RP- 24A NG 12 DRVIN 33A RD 19 DRVIN COM 34A COM 9 P COM 38A CR 8 40A 24V SG 10 CN3 HOME +5V 37A LZ 5 RD TxD 12 HOME COM 36A LZR 15 SD RxD 2 GND 1 LG Personal High limit OV+ 25A GND computer LG 11 Low limit OV- 26A LG 1 RS LG 5 External stop STOP 27A SD Plate CS 15 LG Approx. origin DOG 28A DR CN1E External EMG VTP switching VTP 29A EMG 15 ER External comm. Servo ON ECMD 30A SON 5 Reset Jog reverse JOG- 31A RES 14 Monitor output DC24V Proportional control COM 32A PC 8 4 GND A Torque limit 10k Max. 10mA TL 9 RS 3 5V *3 Normal limit MPG A+ 1A A LSP 16 CS 14 A Reverse limit 10k *3 MPG A- 2A LSN 17 13 DR B MPG B+ 3A SG 10 Plate ER MPG B- 4A 0V SG 20 Within 2m VDD 3 MPG COM 13 RA1 External simultaneous start ALM 18 RA2 failure CON 7A ZSP 19 Emergency stop zero speed detection ENG 8A RA3 TLC 6 in torque limit DC24V COM 10A P15R 11 Analog torque limit TLA 12 +10V/max. current LG 1 SD Plate Within 2m

    12 - 7

     Chapter 12 Operation Order and Installation

4) MR-J?A 连接 (线性驱动)

    optionRevival option Servo motor N C P

    U U R MR-J;A power SM V V S 3 AC200V W W T E R1 S1

    detector CN2 Within 10m

    CN1 G4F-PP1/2/3D SG 13 High limit OV+ 25 14 SG Low limit Servo ON OV- 26 SON 28 External stop Reset STOP 27 RES 29 Approx. origin Torque limit DOG 28 TL 33 VTP switching Normal limit VTP 29 30 LSP Within 30m External comm. Reverse limit LSN ECMD 30 31 Jog reverse JOG- 31 VIN 34 DC24V VDD COM 32 35 CR 32 SG 15 PP 20 FP+ 21 FP- 22 PG 19 22 RP+ 23 NP 21 RP- 24 NG DRVIN 33 RD 24 DRVIN COM 34 1 P15R HOME +5V 37 HOME COM 38 OP 12 VDD 36 RA1 5V detection MPG A+ 1 ZSP 26 A failure ALM 27 MPG A- 2 B SG 16 MPG B+ RA2 3 MPG B- 4 0V MPG External simultaneous start Zero speed CON 7 CN1 Emergency stop EMG 8 P15R 1 DC24V COM 10 TLA 3 ZONE 1 11 Analog torque limit command(+) 6 LG +10V/max. current ZONE 2 12 MO 4 Monitor max. +1mA ZONE 3 13 LG 7 ZONE COM 14 SD 18

    Within 2m

    12 - 8

     Chapter 12 Operation Order and Installation

    5) MR-C?A 连接 (线性驱动)

     Revival resistance (Option) HC-PQ Series motor NF MC U l TE1 U L1 V Power SM V Single phase 200VAC(A type) or W W L2 100VAC(A1 type) Single phase W MR-C;A or MR-C;A1 EMG

    24VDC electronic brake

    OPP of Servo ON signal detector Cutoff by alarm signal Within 10m CN2 G4F-PP/1/2/3D CN1 PP 9 FP+ 21 PG 10 FP- 22 NP 7 RP+ 23 NG 8 RP- 24 CR 13 SG 12 V+ 1 HOME +24V 35 OP 4 HOME COM 38 SD 11 High limit Servo ON SON 17 OV+ 25 Low limit Normal limit LSP 15 OV- 26 External stop LSN 14 Reverse limit STOP 27 Approx. origin ALM 2 failure DOG 28 RA1 VTP switching V24 20 VTP 29 External comm ECMD 30 Jog reverse JOG- 31 COM 32 Driver READY DRVIN 33 DRVIN COM 34 5V MPG A+ 1 A MPG A- 2 B MPG B+ 3 MPG B- 4 0V

    MPG External simultaneous start CON 7 + 24V power Emergency stop ENG 8 supply - DC24V COM 10 ? 24V 0.2A ZONE 1 11 ZONE 2 12 ZONE 3 13 ZONE COM 14

    12 - 9

     Chapter 12 Operation Order and Installation

    6) MINAS A Series 连接 (线性驱动)

    Max. 2m G4F-PP1/2/3D MINAS A

     21 PULSE2 FP+ 21 PULSE1 9 FP- 22 22 SIGN2 RP+ 23 10 SIGN1 RP- 24 HOME +5V 37 37 OZ- OZ+ HOME COM 38 23 35 DRVIN 33 S-RDY+ DRVIN COM 34 34 S-RDY- 29 SRV-QN 5V +5V 9 CCWL MPG A+ 1 A MPG A- 2 8 CWL MPG B MPG B+ 3 7 COM+ 0V MPG B- 4 5G High limit OV+ 25 Low limit OV- 26 External stop STOP 27 Approx. origin DOG 28 VTP switching VTP 29 24G External comm ECMD 30 Jog reverse JOG- 31 P24V COM 32 External simultaneous start CON 7 Emergency stop ENG 8 DC24V COM 10 ZONE 1 11 ZONE 2 12 ZONE 3 13 ZONE COM 14

    7) PYO Series 连接 (线性驱动) Max. 2m G4F-PP1/2/3D PYO

     26 PPC FP+ 21 27 PPC FP- 22 28 CNPC RP+ 23 29 NPC RP- 24 50 5-24VDC 13 SG HOME +24V 35 HOME COM 38 11 COP DRVIN 33 41 SRDY 12-24VDC DRVIN COM 34 49 24 SG 5V +5V MPG A+ A19 25 SG A SON MPG A- B19 37 MPG B MPG B+ A20 32 PROT MPG B- B20 33 NROT 5G 0V 23 5-24VDC High limit OV+ 25 Low limit OV- 26 External stop STOP 27 Approx. origin DOG 28 VTP switching VTP 29 24G External comm ECMD 30 Jog reverse JOG- 31 COM 32 P24V External simultaneous start CON 7 Emergency stop ENG 8 DC24V COM 10 ZONE 1 11 ZONE 2 12 ZONE 3 13 ZONE COM 14

    12 - 10