    PART 1 - GENERAL

    1.1 SUMMARY

    A. Work of this Section consists of exterior and interior sustainable architectural woodwork,

    and includes but is not limited to the following:

    1. Wood cabinets

    2. Paneling

    3. Accessories including, but not limited to, fasteners, hardware, edging, cableways 1.2 SUBMITTALS

    A. Product Data per DIVISION 01 and as follows: Submit manufacturer's printed

    descriptions of materials, components and systems, performance criteria, treatment

    systems, joinery, adhesives, hardware, finishes, use limitations, recommendations and

    installation information.

    NOTE: Choose to use the AWI /AWMAC / WI standards for submittals or as defined by

    the Sections referenced. Delete items not selected.

    B. Shop Drawings per Architectural Woodwork Standards - 2009, Section 1, Submittals. C. Shop Drawings: Submit keyed location plans, detailed and keyed plans and elevations

    indicating materials, dimensions, finishes, hardware, blocking, hanging strips and other

    attachment requirements, cutouts and holes, power, cabling, wiring, built-in appliances

    and equipment.

    1. Field Measurements: Indicate verified field measurements on the Shop Drawings.

    2. For wood casework with transparent finish indicate by elevation veneer leaves with

    dimensions, grain direction, exposed face, and identification numbers indicating the

    flitch and flitch sequence for each leaf.

    3. Use UDS standard notation for elevations, sections and details.

    4. Shop Drawings shall not be copies of the Contract Drawings.

    NOTE: Provide large-scale sections and details, OR a Prototype Mockup for Architect’s

    review and approval. Delete the one not used.

    5. Indicate sections at a min. 3/4” = 1’-0” (1:20) scale and details a minimum half-size

    (1:2).

    6. Provide details and sections indicating each different drawer construction.

    NOTE: Select between the following two items, either review the Prototype Mockup at

     064003 - 1

     CERTFIED ARCHITECTURAL WOODWORK

VERMONT SUSTAINABLE JOBS FUND SHORT-FORM GUIDE SPECIFICATION

    MONTPELIER, VT Last Updated: 05/05/2009

    the fabrication shop or in the field at the jobsite.

    7. Architect to visit shop to view each initial Prototype Mockup piece prior to

    production.

    8. Architect to view each initial Prototype Mockup piece prior to production in situ on

    the job.

    a. Production shall not proceed without Architect’s acceptable review and approval.

    NOTE: Current cutting edge Shop Drawings are based on Architect’s 3-D BIM Drawing

    files. Delete items 5 through 8.a. if using BIM process.

    9. Use 3-D BIM Drawings as base for final Shop Drawings.

    D. Samples: Submit printed color charts and/or sample chains; submit boards, veneer

    flitches and manufactured panel products for final selection. E. Quality Assurance Submittals: Submit Quality Program, Treatment, Content and

    Performance Certificates; Test and Evaluation Reports; and Qualification Statements.

    NOTE: Edit LEED Requirements below to suit project.

    F. Sustainable Design (USGBC LEED?) Submittals:

    1. LEED Credit MR, Materials & Resources. Submit completed LEED-NC 2.2

    Submittal Templates, and other required paperwork as follows:

    a. MR 4.1: 10% Recycled Content, product data

    b. MR 4.2: 20% Recycled Content, product data

    c. MR 5.1: 10% Regional Materials, product data

    d. MR 5.2: 20% Regional Materials, product data

    e. MR 6: Rapidly Renewable Materials, product data

    f. MR 7: FSC Certified Wood, chain-of-custody certificates

    2. LEED Credit EQ, Indoor Environmental Quality. Submit completed LEED-NC 2.2

    Submittal Templates, and required paperwork as follows:

    a. EQ 4.1: Low Emitting Materials, Adhesives & Sealants, VOC Data

    b. EQ 4.2: Low Emitting Materials, Paints & Coatings, VOC Data

    c. EQ 4.4: Low Emitting Materials, Indoor Composite Wood & Agrifiber, No

    Added Urea-Formaldehyde Content product data

    G. Closeout Submittals: Operation and Maintenance Data, Maintenance Bonds, Executed

    Warranty Documentation, and Record Documents.

    NOTE: Edit LEED Requirements below to suit project.

    1. Sustainable Design Closeout Documentation: Submit completed USGBC LEED?

    worksheet templates for the following credits:

    a. MR 4.1, MR 4.2, MR 5.1, MR 5.2, MR 6, MR 7

    b. EQ 4.1, EQ 4.2, EQ 4.4

     064003 - 2

     CERTFIED ARCHITECTURAL WOODWORK

VERMONT SUSTAINABLE JOBS FUND SHORT-FORM GUIDE SPECIFICATION

    MONTPELIER, VT Last Updated: 05/05/2009

1.3 MAINTENANCE MATERIAL SUBMITTALS

    A. Spare Parts: Provide five (5) percent additional sets of each different cabinet hardware

    type and finish.

    1.4 QUALITY ASSURANCE

    A. Qualifications: Fabricator with minimum five (5) years and Installer with minimum three

    (3) years of successful experience.

    1. Fabricator and Supplier shall source wood materials from certified sustainably

    managed forests.

    2. Fabricator and Supplier shall be capable of providing Third Party Certification that

    wood materials were sourced from sustainably managed or certified forests. B. Certifications: Architectural woodwork shall be manufactured and/or installed to the

    specified AWI / AWMAC / WIC JSC Quality Standards.

    1. Source Limitations: Obtain wood timber and manufactured wood products from

    certified sustainably managed forests and displaying the FSC or PEFC or PEFC

    Member label.

    NOTE: Edit sustainability standards and certifications below to suit project. C. Sustainability Standards and Certifications:

    1. Engineered wood shall be made using non-toxic glues, no added formaldehyde

    (NAF), and 100 percent recycled fibers or certified sustainably harvested wood.

    2. Adhesive and Sealant VOC Limits: According to South Coast Air Quality

    Management District (SCAQMD) Rule 1168 and GS-36 for aerosols.

    3. VOC Limits: As tested using U.S. EPA Reference Test Method 24 and as defined by

    a. SCAQMD: In areas where exposure to freeze/thaw conditions and direct

    exposure to moisture will not occur.

    1). SCAQMD Rule 1113, Architectural Coatings

    2). SCAQMD Rule 1168, Adhesive and Sealant Applications

    b. Bay Area Air Quality Management District Regulation (BAAQMD): For

    containers larger than 16 oz., for areas where freeze/thaw conditions do exist or

    direct exposure to moisture can occur.

    1). BAAQMD Regulation 8, Rule 51

    c. California Air Resources Board (CARB): For areas where freeze/thaw conditions

    do exist or direct exposure to moisture can occur.

    1). CARB for containers 16 oz. or less.

    d. Green Seal (GS) Standards:

    1). GS-11, Low Odor or Low VOC Paint

    2). GC-03, Anti-Corrosive Paints, Second Edition, January 7, 1997

    4. Composite wood and agrifiber products shall contain no added urea-formaldehyde

    resins.

    5. Certified Wood Materials: According to FSC-STD-40-004 chain-of-custody

    requirements.

     064003 - 3

     CERTFIED ARCHITECTURAL WOODWORK

VERMONT SUSTAINABLE JOBS FUND SHORT-FORM GUIDE SPECIFICATION

    MONTPELIER, VT Last Updated: 05/05/2009

    D. Mockups: Assemblies required for testing, either in the field or off-site.

    NOTE: Either Mockups or Prototypes may satisfy the designer’s selection process.

    Delete the one not chosen.

    E. Prototypes: Provide materials and full or partial assemblies of each unit type for review

    and approval prior to fabrication production.

    1.5 DELIVERY, STORAGE, AND HANDLING

    A. Delivery, Storage and Handling per manufacturer’s written recommendations, and

    DIVISION 01 requirements.

    1.6 WARRANTY

    NOTE: Coordinate and edit warranty language below to suit Owner requirements and

    Fabricator offering.

    A. Fabricator Warranty: Contractor shall provide fabricator’s guarantee against structural

    defects in materials and workmanship for the lifetime of the original owner beginning on

    the date of Substantial Completion acceptance.

    1. Defective piece(s) shall be repaired or replaced at the discretion of the fabricator, and

    in a timely manner.

    PART 2 - PRODUCTS

    2.1 MANUFACTURERS / FABRICATORS

    GREEN NOTE: For most current list of Vermont FSC Certified Products go to

    http://www.vtwoodnet.org/certified_wood_sources.html .

    A. Fabricator List of FSC Certified VT Casework. (link) Subject to compliance with

    requirements, provide products by one of the following:

    1. Beeken Parsons, Inc., Shelburne, VT; 802.985.2913; www.beekenparsons.com;

    SCS-COC-001477 B

    2. Cotswold Furniture Makers, Stowe, VT; 802.253.3710; http://cotswoldfurniture.com;

    SCS-COC-001477 O

    3. J.S. Benson Woodworking & Design LLC, Brattleboro, VT; 802.254.3515; SCS-

    COC-001477

    4. Stark Mountain Woodworking Company, New Haven, VT; 802.453.5549;

    www.starkmountain.com; SCS-COC-001477 F

    5. William Laberge Cabinetmakers, Inc., Dorset, VT; 802.325.2117;

    www.williamlaberge.com; SCS-COC-001477 N

    B. Fabricator List of VT Cabinetry and Millwork using FSC Certified and Sustainable

    Materials. Subject to compliance with requirements, provide products by one of the

    following:

     064003 - 4

     CERTFIED ARCHITECTURAL WOODWORK

VERMONT SUSTAINABLE JOBS FUND SHORT-FORM GUIDE SPECIFICATION

    MONTPELIER, VT Last Updated: 05/05/2009

    1. Fine Lines in Wood, Inc., New Haven, VT; 802.453.6451; SCS-COC-001477 H

    2