    DESIGN SUBMITTAL

     This gives you some information that will be requested on the sketch and the design submittal. It is not a substitute for knowing the code. There are supplemental checklists for

    other system types

A. Sketch reminders on items to note

    1. Property boundaries and dimensions - Recommend a plat

    2. Boring Locations

    3. Slope

    4. Footprint of all existing or proposed structures including driveways

    5. Compass directions (at least North)

    6. Well location including any neighbors

    a. Federal loans like 100 feet separation

    b. Compression fittings on sewer pipe within 50 feet of well

    i. If this situation occurs make a special note of pipe and all it numbers.

    7. Sketch of the system including a cross section or use extra sheet for x-section

    a) You need to go to the lot and be sure it will fit and check elevations

    b) You will need to show details of the system on the sketch,

    8. Elevations (laser or transit almost a must)

    ; Elevations (at least) four corners for system 18 inches or less in depth and

    non-traditional systems including drainage

    ; Elevations recommended on all systems

    9. Drainage characteristics- tiles, swells, areas that concentrate water, bodies of water.

    10. Jetted tubs of 125 gallons or more?

    11. Fall in the pipe should be noted

    12. Will there be a sump pump, roof drains? Should not be hooked into the septic If

    needed a basement laundry is to be hooked into the septic with its separate sump

    13. Will there be a garbage disposal? Not recommended.

B. Piping - code uses ASTM # it is:

    1. Solid Pipe ASTM #

    a) (PVC) D 2665 D 3034 F 891

    b) (ABS) D 2661 D 2680 D 2751

    c) Pressure Sewer * D 2241 - 89 1785- 89 1527 - 89 2282- 89

    d) 0r waterworks grade ductile iron pipe * (*compression fittings)

    2. Absorption field pipe (perforated)

    a) PVC ASTM D 2729 -89 ABS ASTM F 810 -89

    i. Joints to be glued or other secure connection

    ii. Holes to be 120 degrees apart either two or 3

    iii. Pipe is to placed with holes at 4 and 8 o’clock position

    b) Chamber system experimental at reduced sizing

    c) Stoneless pipe ASTM F667

Page 1 of 3

    Fulton County Health Department

     125 E 9th St. Rochester, IN 46975 (574) 223-7730

     Craig Bugno, MD Health Officer Fax (574) 223-2335

     ______________

    Sketch checklist

C. General Information

    1. General contractor/builder

    2. Septic contractor if out of county address and phone #

    3. Owners

    4. Number of bedrooms __________

    5. Number of jetted tubs over 125 gallons ___________

    6. Garbage disposal

    7. Sump pumps

D. Wells

    1. Separation distance to closest component of the septic system ____________

    2. Neighbor’s well separation distance to closest component of the septic ______

    3. Well should be 50 feet from property lines

E. Residential pipe from house to septic tank

    1. Sewer pipe ASTM ______ see approved piping or list from the code for details

    2. Length from house to septic tank _______________________________

    3. Joint between residential sewer pipe: No joint or

    Waterworks grade ductile iron pipe* Glued, Compression Gasket*, Mechanical*,

    4. Positive fall from house to septic tank:

    ; (4 to 36 inches in 25 feet) or (2-36 in 25 with 6 inch pipe)

F. Septic Tank (pump tank see supplemental sheet)

    1. Tank capacity (size):

    2. Manufacturer

G. Delivery Pipe to D-Box

    1. Sewer pipe ASTM ______ see approved piping or list from the code for details

    ; Length ______ Positive fall and watertight

    2. Joint: No joints Glued Compression Gasket

H. Distribution Box

    1. Note it is to be installed level on undisturbed ground

    2. Material: Concrete Polyethylene Supplier___________________

    3. Baffling Elbow other __________

    4. Number of Outlet holes ____________ Watertight connections

    5. At least 5' of gravity sewer pipe (backfilled with dirt) ASTM__________

Page 2 of 3

    Fulton County Health Department

     125 E 9th St. Rochester, IN 46975 (574) 223-7730

     Craig Bugno, MD Health Officer Fax (574) 223-2335

    -------------------------------------------------------

    I. Gravity Absorption System (sketch

    numbers correspond to numbers below)

    1. Number of trenches: _____

    2. Separation distance _____

    3. If a stone system amounts

    a. Top of pipe ________

    b. Pipe __________

    c. Below the pipe

    4. Synthetic Fabric: Yes No

    5. Trench width ___________

    6. Trench Depth______________

    7. Trench length ______________

    8. Final Depth cover __________

    9. Square feet

    10. Aggregate Type: Washed Gravel Washed limestone (> 3 on Mohs hardness scale)

    11. Lateral pipe 4": PVC ASTM D 2729 ABS ASTM F 810 (Holes at 120 and 240)

    12. Determine level ( trench bottom pipe) by Laser Transit Other (explain)

    13. Absorption field follows contours Yes ___ No ____

    14. Soil will be rolled tested and construction - delayed if needed Yes_____ No_____

    15. If Chambers: Manufacturer________________ Model # _______________

    Number of pieces _____________

    ; If reduced size

    a) 100% replacement area Yes ____ No _____

    b) replacement soils ok Yes _____ No ______

    c) Warranty attached Yes _____ No _____

    16. If Stone less pipe

     Size 8 10 inches

     APPROVED AS SUBMITTED; Yes _______ NO___________

Revised 9-03

    Page 3 of 3