DOC

Container House Specification NO.2

By Victoria Carroll,2014-10-23 15:31
12 views 0
Container House Specification

    SH101

    TECHNICAL SPECIFICATION

    20x8x96ACCOMMODATION CONTAINER

    WITH

    1 PAIR OF FORKLIFT POCKETS

    SPECIFICATION NO. : SH-101

    MODEL NO. : SH-101 stISSUED ON : Mar.21, 2008

1. GENERAL

    The standard container for various purposes is suitable for international container transport. It is of appropriate external dimensions and has connections for lifting and fixing or compounding. The container is designed as a light construction consisting of floor and roof frames and corner profiles. The construction enables compounding of individual containers in longitudinal and transverse directions without limits. It also enables compounding of container in 2 floors height (ground floor+ first floor), or in 3 floors in height for warehousing of these containers (ground floor+ 2 floor).

    The wainscots of the container are made of light insulation panels and offer pleasant climate in the interior due to their building and physical properties.

    Delivery: Containers can be delivered assembled or individually-in kits 648mm high. 4 kits can be bundled in packages2591mm high (ISO dimensions)

2. DIMENSIONS and TARE (ISO Standard 1161)

    -External length 20/ inner length 20’: 6.055m / 50851m

    -External width/ inner width: 2.435m / 2.231m

    -External height/inner height: 20790m / 2.510m

    -Tare: 1950Kgs

3. STTEEL FRAMEWORK

    3.1 Material: cold formed steel profiles in a thickness of 3 to 4mm (bottom rails).

    3.2 Surface working: electric galvanization min 15μm, zinc compatible epoxy ground coat in a

    thickness of 30μm, final zinc compatible vinyl acrylic coat in a thickness of 60-70μm.

    3.3 Fittings: 8 corner fittings (dimensions according to ISO standard 1161). Rainwater pipe in the roof framework, plate thickness of 10mm excluding top corner fittings of the top kit of each bundle (20mm thickness)

    3.4 Forklift openings: openings for fork-lift pockets in the floor framework, dim 88x250mm in a distance of 1200mm

4. FLOOR

4.1 Composition:

    -External wainscot: flat galvanized steel sheet metal in a thickness of 0.5mm. -Insulation filling: non combustible mineral wool in a thickness of 100mm among steel transverse supports. Mineral wool density: 60Kg/m3

    -Steam blockade: PE foil in a thickness of 80μm

    -Plywood panel in a thickness of 18mm

    -Glued PVC flooring covering in a thickness of 1.5mm.

    4.2 Permitted loading: 2.50KN/m2

    4.3 Coefficient of thermal conductivity:=0.039W/Mk

    4.4 R value (Thermal Resistance) =2.56m2K/W

    4.5 XPS insulation option: it is possible to choose an alternative insulation filling: extruded polystyrene (XPS) in a thickness of 80mm among steel transverse supports. XPS density: 35 kgs /cubic meter

    Coefficient of thermal conductivity:=0.029W/Mk

    R value (Thermal Resistance) =2.76m2K/W

5. CEILING

    5.1 composition

    -External wainscot: flat galvanized steel and painted steel sheet metal in a thickness of 0.5mm. -Insulation filling: non combustible mineral wool in a thickness of 100mm among plywood purlins. Mineral wool density: 60Kg/m3

    -Steam blockade: PE foil in a thickness of 80μm

    -Inner wainscot: chip wood panel in a thickness of 9 mm with a foil in white color; joining of chip wood panels with PVC profiles

    5.2 Meteor water outlet: 4 each of PVC rainwater pipes, diameter 50mm in corner pillars 5.3. Permitted loading: 1.50KN/m2

    5.4 Coefficient of thermal conductivity:=0.039W/Mk

    5.5 R value (Thermal Resistance) =2.56m2K/W

6. FACADE WALLS

    6.1 Side panel’s width: 1145mm; total panel thickness: 70mm. Five panels fit into the long side and two panels fit into the short side of container and they are fully interchangeable 6.2 Composition:

    -External wainscot: galvanized and painted steel sheet metal in a thickness of 0.5mm.

     -Insulation filling: non combustible mineral wool in a thickness of 50mm in the wood

    framework. Mineral wool density: 60Kg/m3

    -Inner wainscot: chip wood panel in a thickness of 9 mm with a foil in wood pattern (bright oak

    or white).

    Joining of panels with PVC profiles. Final elements in the interior are made of chip wood panel in a thickness 8 mm with a foil in wood pattern.

    6.3 Permitted loading: 1.00KN/m2

    6.4 Coefficient of thermal conductivity: =0.039W/Mk

    6.5 R value (Thermal Resistance) = 1.28m2K/W

    6.6 100 mm insulation option: the frame work can be modified so that mineral wool insulation

    reaches a thickness of 100mm. In this case R value (Thermal Resistance) goes up to:2.56m2K/W. Note that 100mm thick wall panels are not fully interchangeable like standard 50mm ones

7. DOORS

     Standard external door. Single fold, 40mm thick, made of:

    -a frame in prepainted aluminum

     -hot galvanized and prepainted steel sheets (inside and outside)

    -insulated with PL (polystyrene)

    Opening dimensions of 808*2030mm, furnished with a handle lock with 3 keys Net opening dimensions: 754*1985mm

    Also 845*2000mm net opening is available.

8. WINDOWS

     8.1 Windows

     Option 1: made of PVC, white color, with dimensions 800*1100mm, glazed with double layer glass in a thickness of 4/5/4mm, with sliding mechanism (one side fixed and one sliding)

     Option 2: made of PVC, white color, with dimensions 800*1100mm, glazed with double layer glass in a thickness of 4/5/4mm, with tilt and swing mechanism

     Option 3: made of PVC, white color, with dimensions 800*1200mm, glazed with double layer glass in a thickness of 4/5/4mm, with tilt and swing mechanism

9. ELECTICAL INSTALATIONS

    9.1 Standard: according to VED 100 and CE regulations

    9.2 Voltage: 220V, 60 Hz single phase

    9.3 Network connections: CEE-connection plus/socket, 3-pole 32 A, 220V, mounted on the top frame in upper corners of a shorter side wall

    9.4 Inner distribution system: BVVB cables of suitable dimensions (6, 2.5, 1.5mm), CE marked, flush-mounted. All cabled (located on the ceiling and inside wall panels) run into CE certified plastic conduits. Roof cables and panel cables are connected wit CE compliant jacks.

    All jack connections are protected inside CE marked and IP44 rated distribution boxes. 9.5 Protection: protective current switch (40/2E-0,03A), automatic fuses (B-characteristics) of suitable power (10A, 16A)

    9.6 Earthing: galvanized connector with a steel plate of dimensions 30*80mm welded on the bottom frame

10. Fittings:

     Electric distribution box-1*40/2E-0.03A (protective current switch),1*18A 2*16A(automatic fuses)

    Double fluorescent sockets 220V-2each

    Flush-mounted sockets 220v (SHUKO type)-4 each

    Flush-mounted switches 220V-1 each

    10.1 Remark: Number and arrangement according to the enclosed drawings of standard container types,

11. WARRANTY

     Complete- All components have 1(one) year warranty; paint have 1(one) year warranty.

    12. POSSIBILITIES OF COMTAINER MOUNTING -On a flat solid surface (asphalt, concrete,) -On point foundations (concrete cubes, dimensions 30/30/30cm, 6 pcs/20 container)

    -On band foundations (concrete band, 30cm wide, on the container circumference)

13. EXTRAS

    -2300 and 2700mm internal height;

    -ISO fork-lift pockets, dim. 88*340 in a distance of 2050mm; -Resin floor covering 1mm thick

    -High quality PVC flooring

    -Anti humidity mineral wool

    -Air conditioning 220V 9000(split) or window type) or 220V 12,000 BTU/18000 BTU (split

    type)

    -smoke detector

    -UK and US sockets, double thickness wiring -Windows with (tilt and swing mechanism

    -Venetian blind or sun shade for windows

    -Anti vandal bars for windows

    -Anti vandal gate for door

    -Double door (aluminum frame +PVC panels 1600*2050mm) Anti panic handle

    -Connection kits for long and short side

    14. Remark: Rights to technical changes are withheld.