PLC-parallel-input, 24V DC for external program selection Multi-pin connectors, separated for sensors and power or mixed, according to customer s request...

    26-29 4 2006

    Shanghai New International Expo Centre, Pudong, Shanghai, PR China

Immediate Release

    MCS series from FELLER ENGINEERING

    The MCS series will participate in Asias No. 1 plastic and rubber show, Chinaplas 2006 (The 20th International Exhibition on Plastics and Rubber Industries), from April 26th to 29th at the Shanghai New

    International Expo Centre, Shanghai, PR China.

The MCS series of Hotrunner Temperature Controller is a consistent development of the well known and

    proven history in the market of Hotrunner Controllers from FELLER ENGINEERING.

The power of the MCS series bases on long time close working relation and experience with the plastic

    processing industry.

Special efforts were made to design a state of the art temperature controller which fulfils user friendliness.

    The actual MCS generation joins modern technical comfort with easy operation and a extremely service

    friendly internal structure as well as highest degree at an attractive price.

    Features

    ? Aluminium profile frame, closed housing, IP20, construction 19” width

    ? Number of zones up to 270

    ? reduced depth up 31 zones, 400 mm (16”)

    ? Layout for 31 to 90 control zones per unit

    ? Flappable front panel

    ? Optional lockable casters

    ? Potential free alarm output via 7 pin plug

    ? Data interface (optional RS232, RS422, RS485, TTY, Bluetooth)

    ? Heater current supervision

    ? Maximum power per zone 230VAC / 16A at 80% duty cycle

    ? NSS fuses (line voltage protection for sensor input >10V)

    ? Power cord 3 m (10ft.) with CEE plug

    ? Safety shut-off via main power relay

    ? Fuse for control voltage 4A medium blow

    ? Fuse for power outputs, 16A superfast blow

    ? Power triacs

    ? PLC-parallel-input, 24V DC for external program selection

    ? Multi-pin connectors, separated for sensors and power or mixed, according to customer?s request

    ? Configurable for or Y power supply

    ? 50 or 60 Hz/cps

    ? Internal resolution ?? C (0,45?F)

    ? Diagnostic program to check external wiring mistakes

     主辦單位 Organizer : 雅式展覽服務有限公司 Adsale Exhibition Services Ltd 電話 Tel : (852) 2811 8897 傳真 Fax : (852) 2516 5024

     電郵 Email : chinaplas@adsale.com.hk 網址 Website :

    www.2456.com/chinaplas

    26-29 4 2006

    Shanghai New International Expo Centre, Pudong, Shanghai, PR China

    ? Classification of zones at start command

    ? Current leakage detection with intelligent dry-out routine

    ? Soft-start function

    ? Storage capacity for 4 set-point programs including stand-by and boost-mode

    ? Manual operation or automatic activation based on mean/preset or value of neighbouring zone at

    sensor fault

    ? Combined heating-up mode

    ? Operation via proven foil key pad

    ? Selectable on over-all display: set point, actual value, deviation, regulation rate and heater current

    draw

    ? Copy function

    ? Supervision of output rate: An accepted range is set by a parameter for tolerance. Deviations will be

    apparent and reported after a selectable time out of the tolerance for the supervision.

    ? Spares inside: Depending on the size of the controller in unit there is to find a minimum of 2 triacs, 3

    output fuses 16A FF and 4 NSS- fuses 100mA F

    ? Limited boost function: The setting of a limit for setpoints disables the overheating of this value for

    more than 10 min.

    Functional description

Easy operation, with clear positions of keys and displays combined with a stable control structure for industry

    based design are the main features of the series of MCS controllers.

    After the power is switched on, the MCS controller drives towards the chosen set point recognizing whether

    or not it is necessary to dry out the heaters at 100?C (212?F). To avoid unequal heating of the different

    components during the dry out phase all zones are blocked at 100?C (212?F). Following the combined

    heating routine enables to reach the set point nearly simultaneously. Continuous control of the slow heaters

    substitutes to heat up via fixed ramps.

Error messages (broken sensor, reversed polarity on sensor, over/under temperature, current leakage, and

    system fault) are displayed on the front panel. An additional 7-pin female connector at the rear of the unit is

    provided for external analysis of errors. In case of sensor loss the controller may switch automatically into

    manual mode. Depending on the configuration the controller will use the averaged manual output rate. The

    respective zone(s) can also be linked with a similar zone to synchronize the heating.

Up to 270 zones with multiples of MCS control units can be operated by one MCS control (Pentium based

    industrial PC with Touch Screen Monitor). The touch screen monitor of the MCS control allows simple

    operation of molds with large cavitations. The final feature of the MCS series is MCS+. These units are

    stackable (max. 90 zones consisting of 6 units) and connected via external bus interface, which gives a

    maximum flexibility for operation of molds with different cavitations.

     主辦單位 Organizer : 雅式展覽服務有限公司 Adsale Exhibition Services Ltd 電話 Tel : (852) 2811 8897 傳真 Fax : (852) 2516 5024

     電郵 Email : chinaplas@adsale.com.hk 網址 Website :

    www.2456.com/chinaplas

    26-29 4 2006

    Shanghai New International Expo Centre, Pudong, Shanghai, PR China

FELLER ENGINEERING also customizes cables as well as the industry proven Software FECON. The

    process control system enables the remote control and monitoring of MCS units via PC

As the largest scale in history, Chinaplas 2006 will reach an exhibition area of 92,000 sqm, with participation

    of 1,300 exhibitors and ten group pavilions from Austria, Canada, Germany, India, Italy, Japan, PR China and

    Taiwan Province, United Kingdom and USA. There will be demonstration of over 1,000 sets of machines as

    well as a wide range of chemicals and raw materials.

Chinaplas 2006 is organized by Adsale Exhibition Services Ltd., co-organized by China National Light

    Industry Council - China Plastics Processing Industry Association, Messe Düsseldorf China Ltd., Shanghai

    Society of Plastics Industry and International Trade Promotion Corporation, and sponsored exclusively by

    European Committee of Machinery Manufacturers for the Plastics & Rubber Industries (EUROMAP) in

    China.

Online pre-registered visitors will enjoy free admission (waive admission fee RMB20) and many privileges.

    For online pre-registration and further show information, please feel free to visit www.2456.com/chinaplas.

    For enquiries on visiting, please contact Tel: (86 21) 6427 3630 ext 273 / chinaplas_visitor@adsale.com.hk.

    ** END** Issued by Adsale Exhibition Services Ltd.

    For press enquiry, please contact Ms. Vivien Wong / Ms. Karen Cheung:

    Unit 1101-6, 11/F, Island Place Tower, 510 Kings Road, North Point, Hong Kong Tel: 852 2516 3340 / 2516 3374 Fax: 852 2516 5024

    E-mail: publicity@adsale.com.hk

    Adsale Group: www.adsale.com.hk Adsale Content Network: www.2456.com

     主辦單位 Organizer : 雅式展覽服務有限公司 Adsale Exhibition Services Ltd 電話 Tel : (852) 2811 8897 傳真 Fax : (852) 2516 5024

     電郵 Email : chinaplas@adsale.com.hk 網址 Website :

    www.2456.com/chinaplas

Report this document

For any questions or suggestions please email
cust-service@docsford.com