    Product Description Sheet

    1001 Trout Brook Crossing?Rocky Hill, CT 06067-3910 Fixmaster Fast Set Grout Telephone: (860) 571-5100FAX: (860) 571-5465Maintenance, Repair & Operations, May 1999

    PRODUCT DESCRIPTION

    ? ?3LOCTITEFixmaster Fast Set Grout is designed to grout per 2 gallon 3new machinery and to set anchor bolts quickly. Self-leveling 347 in per 2 gallon epoxy can be poured up to 2.54 cm (1”) thick. Cured material TYPICAL CURING PERFORMANCE has compression strength and chemical resistance superior to Curing Properties concrete under typical dry service temperatures of 29? to Typical Value (@ 25?C unless noted) Working Life, minutes 10 +93?C (20? to +200?F). And unlike concrete, it forms strong Mix Ratio (R:H) by Volume 100:11.7 Cure Time, hours 12 by Weight 100:6.5 bonds to old concrete and to itself. Coverage 5.7 dm

    TYPICAL PROPERTIES OF CURED MATERIAL Advantages:

    (@ 25?C unless noted) ? Solids epoxy system non-shrinking chemical resistant Physical Properties Typical Value ? Stronger than concrete long-lasting 2Compressive Strength, ASTM D695, psi (N/mm) 14,500 (100) ? Fast and easy to use reduces downtime 2Shear Strength ASTM D1002, psi (N/mm) 1,700 (11.7) ? Self-leveling application versatility, corrosion resistant .005” gap, acid etched aluminum 2Tensile Strength ASTM D638, psi (N/mm) 4,500 (31.0) TYPICAL APPLICATIONS ? Grouting in pumps GENERAL INFORMATION ? Level machinery This product is not recommended for use in pure oxygen ? Set anchor bolts and/or oxygen rich systems and should not be selected ? Grouting in lathes and compressors as a sealant for chlorine or other strong oxidizing ? Use from 2.54cm (1”) to 0.32 cm (1/8”) clearance materials. DIRECTIONS FOR USE For safe handling information on this product, consult 1. The area to be grouted must be cleaned of all loose the Material Safety Data Sheet, (MSDS). material. Sole plates, rails and machinery bases must be cleaned of rust, grease, and oil. New concrete should be Ordering Information scarified for good bonding. Use grease or mold release Part Number Container Size on all forms and areas where grout should not adhere. 39637 2 gallon kit 2. Sole plates, rail and foundation must be above 10?C (50?F) for proper hardening of the grout. Storage 3. Open pail and remove small can (hardener) and plastic Product shall be ideally stored in a cool, dry location in liner.

    unopened containers at a temperature between 8?C to 28?C 4. Premix hardener by shaking can. Premix resin in 2 gal

    pail. (46?F to 82?F) unless otherwise labeled. Optimal storage is 5. Add contents of small can (hardener) and mix until at the lower half of this temperature range. To prevent uniform in color. contamination of unused product, do not return any material 6. Pour immediately after mixing, to a maximum thickness to its original container. For further specific shelf life of 2.54 cm (1”). If thicker sections are required, pour in information, contact your local Technical Service Center. layers after the previous one is tack-free and cooled, but within 12 hours. Data Ranges The data contained herein may be reported as a typical value TECHNICAL TIPS FOR WORKING WITH EPOXIES and/or range. Values are based on actual test data and are Working time and cure time depends on temperature and verified on a periodic basis. mass: ? The higher the temperature, the faster the cure. Note The data contained herein are furnished for information only and are ? The larger the mass of material mixed, the faster the believed to be reliable. We cannot assume responsibility for the results cure. obtained by others over whose methods we have no control. It is the To speed the cure of epoxies at low temperatures: user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as ? Store epoxy at room temperature. may be advisable for the protection of property and of persons against any ? Pre-heat repair surface until warm to the touch. hazards that may be involved in the handling and use thereof. In light of To slow the cure of epoxies at high temperatures: the foregoing, Loctite Corporation specifically disclaims all warranties expressed or implied, including warranties of ? Mix epoxy in small masses to prevent rapid curing. merchantability or fitness for a particular purpose, arising from ? Cool resin/hardener component(s). sale or use of Loctite Corporation’s products. Loctite Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits. The discussion herein of PROPERTIES OF UNCURED MIXED MATERIAL various processes or compositions is not to be interpreted as Mixture Typical Value Appearance Red Liquid

    NOT FOR PRODUCT SPECIFICATIONS. THE TECHNICAL DATA CONTAINED HEREIN ARE INTENDED AS REFERENCE ONLY. PLEASE CONTACT LOCTITE CORPORATION QUALITY DEPARTMENT FOR ASSISTANCE AND RECOMMENDATIONS ON SPECIFICATIONS FOR THIS PRODUCT. ROCKY HILL, CT FAX: +1 (860)-571-5473 DUBLIN, IRELAND FAX: +353-(1)-451 9959 Loctite and Fixmaster are Trademarks of Loctite Corporation U.S.A.

? PDS FIXMASTER FAST SET GROUT, May 1999

representation that they are free from domination of patents owned by others or as a license under any Loctite Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. One or more United States or foreign patents or patent applications may cover this product.

Fixmaster is a Registered Trademark of Loctite Corporation, Hartford, CT 06106