    Product Description Sheet

    1001 Trout Brook Crossing?Rocky Hill, CT 06067-3910 Fixmaster Deep Pour Grout Telephone: (860) 571-5100FAX: (860) 571-5465Maintenance, Repair & Operations May 1999

    PRODUCT DESCRIPTION ? Store epoxy at room temperature. ? ?LOCTITEFixmaster Deep Pour Grout aggregate filled ? Pre-heat repair surface until warm to the touch. epoxy system is designed for grouting up to 15.2 cm (6”) To slow the cure of epoxies at high temperatures: deep, including self-leveling applications under rails and sole ? Mix epoxy in small masses to prevent rapid curing. plates under typical dry service temperatures of 29? to ? Cool resin/hardener component(s). +107?C (20? to +225?F). Withstands high torque PROPERTIES OF UNCURED MIXED MATERIAL loading. Mixture Typical Value Appearance Thick Black Liquid Advantages: Mix Ratio (R:H) by Volume 4.05:1 to 8.21 Filler by Weight 16.4:3.6 to 80 Filler ? Solids epoxy system, non-shrinking, chemical resistant Coverage 10.8 dm3 per 5 gal ? Self-leveling, application versatility, corrosion resistant 3 660 in per 5 gal ? Fast and easy to use, reduces downtime ? Stronger than concrete, long lasting TYPICAL CURING PERFORMANCE Curing Properties TYPICAL APPLICATIONS Typical Value (@ 25?C unless noted) ? Diesel or gas engines, generators Working Life, minutes 30 Cure Time, hours 24 ? Cones crushers ? Compressors TYPICAL PROPERTIES OF CURED MATERIAL ? Mine hoists (@ 25?C unless noted) ? Outboard bearings Physical Properties Typical Value 2? Gantry cranes Compressive Strength, ASTM D695, psi (N/mm) 14,500 (100) ? For pours up to 15.2 cm (6”) thick GENERAL INFORMATION DIRECTIONS FOR USE This product is not recommended for use in pure oxygen 1. Prepare area to be grouted. Make sure foundation is and/or oxygen rich systems and should not be selected above 10?C (50?F). The grout is not recommended for as a sealant for chlorine or other strong oxidizing use below 10?C (50?F). materials. 2. Remove the two cans and filler from the 5 gallon pail. 3. Pour all contents of the resin into the 5 gallon pail. Shake For safe handling information on this product, consult the hardener can to premix then add all of the hardener to the Material Safety Data Sheet, (MSDS). the resin in the 5 gallon pail. Mix the resin and hardener Ordering Information together for 3 minutes.

    Part Number Container Size 4. Gradually add the filler to the 5 gallon pail and mix until

    there is no dry powder present. 99545 5 gal kit 5. Total mixing time from start to finish should not take Storage more than 15 minutes or the mixture will harden before Product shall be ideally stored in a cool, dry location in unopened mixed grout can be poured. containers at a temperature between 8?C to 28?C (46?F to 82?F) unless otherwise labeled. Optimal storage is at the lower half of this temperature 6. Pour into area to be grouted immediately after mixing to range. To prevent contamination of unused product, do not return any give maximum flow before set up. At 25?C (77?F) material to its original container. For further specific shelf life information, working time is 30 minutes and material will be contact your local Technical Service Center. functionally cured in 24 hours. For grouting applications greater than 15.2 cm (6”), pour in 10.2 cm (4”) Data Ranges increments. Allow previous grout to become tack-free The data contained herein may be reported as a typical value and/or range. Values are based on actual test data and are verified on a periodic and cool before making subsequent pours. Before basis. making additional pours, be sure previous poured surface is clean and dry free from dust, oil and moisture. Note 7. Allow epoxy grout to harden before starting machinery. The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results 8. See warning labels on packages for safe handling obtained by others over whose methods we have no control. It is the procedures. user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as TECHNICAL TIPS FOR WORKING WITH EPOXIES may be advisable for the protection of property and of persons against any Working and cure time depends on temperature and hazards that may be involved in the handling and use thereof. In light of the foregoing, Loctite Corporation specifically disclaims all mass: warranties expressed or implied, including warranties of ? The higher the temperature, the faster the cure. merchantability or fitness for a particular purpose, arising from ? The larger the mass of material mixed, the faster the sale or use of Loctite Corporation’s products. Loctite Corporation specifically disclaims any liability for consequential or incidental cure.

    To speed the cure of epoxies at low temperatures:

    NOT FOR PRODUCT SPECIFICATIONS. THE TECHNICAL DATA CONTAINED HEREIN ARE INTENDED AS REFERENCE ONLY. PLEASE CONTACT LOCTITE CORPORATION QUALITY DEPARTMENT FOR ASSISTANCE AND RECOMMENDATIONS ON SPECIFICATIONS FOR THIS PRODUCT. ROCKY HILL, CT FAX: +1 (860)-571-5473 DUBLIN, IRELAND FAX: +353-(1)-451 9959 Loctite and Fixmaster are Trademarks of Loctite Corporation U.S.A.

? PDS FIXMASTER DEEP POUR GROUT, May 1999

damages of any kind, including lost profits. The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Loctite Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. One or more United States or foreign patents or patent applications may cover this product.

Fixmaster is a Registered Trademark of Loctite Corporation, Hartford, CT 06106